Correlation of Measurements of the Prearthritic Hip Between Plain Radiography and Computed Tomography. Issue 2 (8th February 2019)
- Record Type:
- Journal Article
- Title:
- Correlation of Measurements of the Prearthritic Hip Between Plain Radiography and Computed Tomography. Issue 2 (8th February 2019)
- Main Title:
- Correlation of Measurements of the Prearthritic Hip Between Plain Radiography and Computed Tomography
- Authors:
- Air, Mary E.
Harrison, Julian R.
Nguyen, Joseph T.
Kelly, Bryan T.
Bogner, Eric A.
Moley, Peter J. - Abstract:
- Abstract : Background: Previous studies have compared radiographic and computed tomography (CT) imaging for the evaluation of prearthritic hip pain. However, the intermodality, interrater, and intrarater consistencies of those parameters have not been investigated. Objective: To determine whether radiographs with an anteroposterior pelvis view and 45°‐Dunn lateral view reliably correlate with CT in the context of lateral center edge (LCE), Tonnis, alpha, and beta angle measurements for femoroacetabular impingement or hip dysplasia diagnosis. Design: Retrospective study. Setting: Academic orthopedic institution. Patients: Fifty consecutive participants with hip pain in the institutional hip registry with radiographs and CT imaging on file were evaluated between 2013 and 2014. Materials and Methods: Radiologic data (50 CTs and 50 radiographs) were evaluated by 3 physicians. LCE, Tonnis, alpha, and beta angles were measured on radiographs and CTs in 2 rounds of readings. In round 1, the center of rotation on CT imaging was standardized by 1 rater. In round 2, individual raters chose CT images using a quadrant method, and reproducibility was assessed. Reliability statistics were operationalized with intraclass correlation coefficients (ICCs). Main Outcome Measurements: Intermodality, intrarater, and interrater reliability of CT vs radiographic measurements. Results: The intermodality reliability for all raters was excellent (ICC [95% CI]: 0.84 [0.76‐0.90] to 0.97 [0.96‐0.98]).Abstract : Background: Previous studies have compared radiographic and computed tomography (CT) imaging for the evaluation of prearthritic hip pain. However, the intermodality, interrater, and intrarater consistencies of those parameters have not been investigated. Objective: To determine whether radiographs with an anteroposterior pelvis view and 45°‐Dunn lateral view reliably correlate with CT in the context of lateral center edge (LCE), Tonnis, alpha, and beta angle measurements for femoroacetabular impingement or hip dysplasia diagnosis. Design: Retrospective study. Setting: Academic orthopedic institution. Patients: Fifty consecutive participants with hip pain in the institutional hip registry with radiographs and CT imaging on file were evaluated between 2013 and 2014. Materials and Methods: Radiologic data (50 CTs and 50 radiographs) were evaluated by 3 physicians. LCE, Tonnis, alpha, and beta angles were measured on radiographs and CTs in 2 rounds of readings. In round 1, the center of rotation on CT imaging was standardized by 1 rater. In round 2, individual raters chose CT images using a quadrant method, and reproducibility was assessed. Reliability statistics were operationalized with intraclass correlation coefficients (ICCs). Main Outcome Measurements: Intermodality, intrarater, and interrater reliability of CT vs radiographic measurements. Results: The intermodality reliability for all raters was excellent (ICC [95% CI]: 0.84 [0.76‐0.90] to 0.97 [0.96‐0.98]). Intrarater reliability for both modalities showed excellent reliability (ICC = 0.75‐0.96). Interrater reliability of CT measures of LCE, Tonnis, and alpha angles demonstrated excellent agreement (ICC ≥ 0.88). Beta angle measures demonstrated good agreement (ICC [95% CI] = 0.68 [0.49‐0.81]). Interrater reliability of radiographic measures showed excellent agreement (ICC = 0.82‐0.94). Conclusion: Equivalent angle measurement readings on CT and radiographs were consistent among physicians. CT measurements correlated well with radiographic measurements. This suggests that if a standardized procedure is used to find the center of the femoral head, a positive correlation among LCE, alpha, beta, and Tonnis angles measured on CT can be obtained between multiple readers. Level of Evidence: III … (more)
- Is Part Of:
- PM&R. Volume 11:Issue 2(2019)
- Journal:
- PM&R
- Issue:
- Volume 11:Issue 2(2019)
- Issue Display:
- Volume 11, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 11
- Issue:
- 2
- Issue Sort Value:
- 2019-0011-0002-0000
- Page Start:
- 158
- Page End:
- 166
- Publication Date:
- 2019-02-08
- Subjects:
- Medical rehabilitation -- Periodicals
Physical therapy -- Periodicals
Physical Therapy Modalities -- Periodicals
615.5 - Journal URLs:
- https://onlinelibrary.wiley.com/journal/19341563 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.pmrj.2018.06.001 ↗
- Languages:
- English
- ISSNs:
- 1934-1482
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6541.077150
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10082.xml