A reanalysis of football impact reconstructions for head kinematics and finite element modeling. (April 2019)
- Record Type:
- Journal Article
- Title:
- A reanalysis of football impact reconstructions for head kinematics and finite element modeling. (April 2019)
- Main Title:
- A reanalysis of football impact reconstructions for head kinematics and finite element modeling
- Authors:
- Sanchez, Erin J.
Gabler, Lee F.
Good, Ann B.
Funk, James R.
Crandall, Jeff R.
Panzer, Matthew B. - Abstract:
- Abstract: Background: Head kinematics generated by laboratory reconstructions of professional football helmet impacts have been applied to computational models to study the biomechanics of concussion. Since the original publication of this data, techniques for evaluating accelerometer consistency and error correction have been developed. This study applies these techniques to the original reconstruction data and reanalyzes the results given the current state of concussion biomechanics. Methods: Consistency checks were applied to the sensor data collected in the head of each test dummy. Inconsistent data were corrected using analytical techniques, and head kinematics were recalculated from the corrected data. Reconstruction videos were reviewed to identify artefactual impacts during the reconstruction to establish the region of applicability for simulations. Corrected head kinematics were input into finite element brain models to investigate strain response to the corrected dataset. Findings: Multiple reconstruction cases had inconsistent sensor arrays caused by a problematic sensor; corrections to the arrays caused changes in calculated rotational head motion. These corrections increased median peak angular velocity for the concussion cases from 35.6 to 41.5 rad/s. Using the original kinematics resulted in an average error of 20% in maximum principal strain results for each case. Simulations of the reconstructions also demonstrated that simulation lengths less than 40 ms didAbstract: Background: Head kinematics generated by laboratory reconstructions of professional football helmet impacts have been applied to computational models to study the biomechanics of concussion. Since the original publication of this data, techniques for evaluating accelerometer consistency and error correction have been developed. This study applies these techniques to the original reconstruction data and reanalyzes the results given the current state of concussion biomechanics. Methods: Consistency checks were applied to the sensor data collected in the head of each test dummy. Inconsistent data were corrected using analytical techniques, and head kinematics were recalculated from the corrected data. Reconstruction videos were reviewed to identify artefactual impacts during the reconstruction to establish the region of applicability for simulations. Corrected head kinematics were input into finite element brain models to investigate strain response to the corrected dataset. Findings: Multiple reconstruction cases had inconsistent sensor arrays caused by a problematic sensor; corrections to the arrays caused changes in calculated rotational head motion. These corrections increased median peak angular velocity for the concussion cases from 35.6 to 41.5 rad/s. Using the original kinematics resulted in an average error of 20% in maximum principal strain results for each case. Simulations of the reconstructions also demonstrated that simulation lengths less than 40 ms did not capture the entire brain strain response and under-predicted strain. Interpretation: This study corrects data that were used to determine concussion risk, and indicates altered head angular motion and brain strain response for many reconstructions. Conclusions based on the original data should be re-examined based on this new study. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 64(2019)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 64(2019)
- Issue Display:
- Volume 64, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 64
- Issue:
- 2019
- Issue Sort Value:
- 2019-0064-2019-0000
- Page Start:
- 82
- Page End:
- 89
- Publication Date:
- 2019-04
- Subjects:
- Laboratory reconstructions -- Head kinematics -- Finite element model -- Brain strain -- Concussion -- Football
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2018.02.019 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10072.xml