Fluid responsiveness in acute circulatory failure. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Fluid responsiveness in acute circulatory failure. Issue 1 (December 2015)
- Main Title:
- Fluid responsiveness in acute circulatory failure
- Authors:
- Hasanin, Ahmed
- Abstract:
- Abstract Although fluid resuscitation of patients having acute circulatory failure is essential, avoiding unnecessary administration of fluids in these patients is also important. Fluid responsiveness (FR) is defined as the ability of the left ventricle to increase its stroke volume (SV) in response to fluid administration. The objective of this review is to provide the recent advances in the detection of FR and simplify the physiological basis, advantages, disadvantages, and cut-off values for each method. This review also highlights the present gaps in literature and provides future thoughts in the field of FR. Static methods are generally not recommended for the assessment of FR. Dynamic methods for the assessment of FR depend on heart-lung interactions. Pulse pressure variation (PPV) and stroke volume variation (SVV) are the most famous dynamic measures. Less-invasive dynamic parameters include plethysmographic-derived parameters, variation in blood flow in large arteries, and variation in the diameters of central veins. Dynamic methods for the assessment of FR have many limitations; the most important limitation is spontaneous breathing activity. Fluid challenge techniques were able to overcome most of the limitations of the dynamic methods. Passive leg raising is the most popular fluid challenge method. More simple techniques have been recently introduced such as the mini-fluid challenge and 10-s fluid challenge. The main limitation of fluid challenge techniques is theAbstract Although fluid resuscitation of patients having acute circulatory failure is essential, avoiding unnecessary administration of fluids in these patients is also important. Fluid responsiveness (FR) is defined as the ability of the left ventricle to increase its stroke volume (SV) in response to fluid administration. The objective of this review is to provide the recent advances in the detection of FR and simplify the physiological basis, advantages, disadvantages, and cut-off values for each method. This review also highlights the present gaps in literature and provides future thoughts in the field of FR. Static methods are generally not recommended for the assessment of FR. Dynamic methods for the assessment of FR depend on heart-lung interactions. Pulse pressure variation (PPV) and stroke volume variation (SVV) are the most famous dynamic measures. Less-invasive dynamic parameters include plethysmographic-derived parameters, variation in blood flow in large arteries, and variation in the diameters of central veins. Dynamic methods for the assessment of FR have many limitations; the most important limitation is spontaneous breathing activity. Fluid challenge techniques were able to overcome most of the limitations of the dynamic methods. Passive leg raising is the most popular fluid challenge method. More simple techniques have been recently introduced such as the mini-fluid challenge and 10-s fluid challenge. The main limitation of fluid challenge techniques is the need to trace the effect of the fluid challenges on SV (or any of its derivatives) using a real-time monitor. More research is needed in the field of FR taking into consideration not only the accuracy of the method but also the ease of implementation, the applicability on a wider range of patients, the time needed to apply each method, and the feasibility of its application by acute care physicians with moderate and low experience. … (more)
- Is Part Of:
- Journal of intensive care. Volume 3:Issue 1(2015)
- Journal:
- Journal of intensive care
- Issue:
- Volume 3:Issue 1(2015)
- Issue Display:
- Volume 3, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 3
- Issue:
- 1
- Issue Sort Value:
- 2015-0003-0001-0000
- Page Start:
- 1
- Page End:
- 8
- Publication Date:
- 2015-12
- Subjects:
- Fluid responsiveness -- Acute circulatory failure -- Heart-lung interaction -- Fluid challenge
Critical care medicine -- Periodicals
Intensive care units -- Periodicals
616.028 - Journal URLs:
- http://jintensivecare.biomedcentral.com/ ↗
http://www.jintensivecare.com/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s40560-015-0117-0 ↗
- Languages:
- English
- ISSNs:
- 2052-0492
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10066.xml