Incidences and influences of device-associated healthcare-associated infections in a pediatric intensive care unit in Japan: a retrospective surveillance study. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Incidences and influences of device-associated healthcare-associated infections in a pediatric intensive care unit in Japan: a retrospective surveillance study. Issue 1 (December 2015)
- Main Title:
- Incidences and influences of device-associated healthcare-associated infections in a pediatric intensive care unit in Japan: a retrospective surveillance study
- Authors:
- Hatachi, Takeshi
Tachibana, Kazuya
Takeuchi, Muneyuki - Abstract:
- Abstract Background Device-associated healthcare-associated infections (DA-HAIs) are a major problem in pediatric intensive care units (PICUs). However, there are no data available regarding the incidences of DA-HAIs in PICUs in Japan and their influences on length of PICU stay and mortality. The objective of this study was to investigate the incidences of three common DA-HAIs in a PICU and their influences on length of PICU stay and mortality in Japan. Methods We performed a retrospective surveillance study over 12 months in a single PICU in Japan. First, we investigated the incidences of three common DA-HAIs: central line-associated bloodstream infections (CLABSI), ventilator-associated pneumonia (VAP), and catheter-associated urinary tract infection (CAUTI) by chart review, according to the surveillance definitions of the Centers for Disease Control and Prevention/National Healthcare Safety Network. Second, we compared patient characteristics, morbidity, and mortality between the patients with and without DA-HAIs. Results Of all 426 patients admitted to the PICU, 73 % had a central venous catheter, 75 % had an endotracheal tube, and 81 % had a urinary catheter during their PICU stay; the device utilization ratios per patient-days for these were 0.78, 0.53, and 0.44, respectively. In total, 28 patients (6.6 %) acquired at least one of the three DA-HAIs investigated, with an overall incidence per 1000 patient-days of 11.2. The incidences of CLABSI, VAP, and CAUTI per 1000Abstract Background Device-associated healthcare-associated infections (DA-HAIs) are a major problem in pediatric intensive care units (PICUs). However, there are no data available regarding the incidences of DA-HAIs in PICUs in Japan and their influences on length of PICU stay and mortality. The objective of this study was to investigate the incidences of three common DA-HAIs in a PICU and their influences on length of PICU stay and mortality in Japan. Methods We performed a retrospective surveillance study over 12 months in a single PICU in Japan. First, we investigated the incidences of three common DA-HAIs: central line-associated bloodstream infections (CLABSI), ventilator-associated pneumonia (VAP), and catheter-associated urinary tract infection (CAUTI) by chart review, according to the surveillance definitions of the Centers for Disease Control and Prevention/National Healthcare Safety Network. Second, we compared patient characteristics, morbidity, and mortality between the patients with and without DA-HAIs. Results Of all 426 patients admitted to the PICU, 73 % had a central venous catheter, 75 % had an endotracheal tube, and 81 % had a urinary catheter during their PICU stay; the device utilization ratios per patient-days for these were 0.78, 0.53, and 0.44, respectively. In total, 28 patients (6.6 %) acquired at least one of the three DA-HAIs investigated, with an overall incidence per 1000 patient-days of 11.2. The incidences of CLABSI, VAP, and CAUTI per 1000 device-days were 4.3, 3.5, and 13.6, respectively. The median length of PICU stay for the patients with DA-HAIs was 22.5 days, compared with 2 days for those without DA-HAIs. Although there was no statistical difference, the mortality of the patients with DA-HAIs was 7.1 %, whereas the mortality of the patients without DA-HAIs was 2.3 %. Conclusions This study showed the incidences of three common DA-HAIs in a PICU in Japan, and that they were associated with a longer length of PICU stay. … (more)
- Is Part Of:
- Journal of intensive care. Volume 3:Issue 1(2015)
- Journal:
- Journal of intensive care
- Issue:
- Volume 3:Issue 1(2015)
- Issue Display:
- Volume 3, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 3
- Issue:
- 1
- Issue Sort Value:
- 2015-0003-0001-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2015-12
- Subjects:
- Device-associated healthcare-associated infection -- Nosocomial -- Bloodstream infection -- Ventilator-associated pneumonia -- Urinary tract infection -- Pediatric intensive care unit -- Japan -- Incidence
Critical care medicine -- Periodicals
Intensive care units -- Periodicals
616.028 - Journal URLs:
- http://jintensivecare.biomedcentral.com/ ↗
http://www.jintensivecare.com/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s40560-015-0111-6 ↗
- Languages:
- English
- ISSNs:
- 2052-0492
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10066.xml