Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs. Issue 1 (December 2017)
- Record Type:
- Journal Article
- Title:
- Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs. Issue 1 (December 2017)
- Main Title:
- Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs
- Authors:
- Ballo, Haitham
Tarkia, Miikka
Haavisto, Matti
Stark, Christoffer
Strandberg, Marjatta
Vähäsilta, Tommi
Saunavaara, Virva
Tolvanen, Tuula
Teräs, Mika
Hynninen, Ville-Veikko
Savunen, Timo
Roivainen, Anne
Knuuti, Juhani
Saraste, Antti - Abstract:
- Abstract Background We evaluated echocardiographic area-length methods to measure left ventricle (LV) volumes and ejection fraction (EF) in parasternal short axis views in comparison with cardiac computed tomography (CT) in pigs with chronic myocardial infarction (MI). Methods Male farm pigs with surgical occlusion of the left anterior descending coronary artery (n = 9) or sham operation (n = 5) had transthoracic echocardiography and cardiac-CT 3 months after surgery. We measured length of the LV in parasternal long axis view, and both systolic and diastolic LV areas in parasternal short axis views at the level of mitral valve, papillary muscles and apex. Volumes and EF of the LV were calculated using Simpson's method of discs (tri-plane area) or Cylinder-hemiellipsoid method (single plane area). Results The pigs with coronary occlusion had anterior MI scars and reduced EF (average EF 42 ± 10%) by CT. Measurements of LV volumes and EF were reproducible by echocardiography. Compared with CT, end-diastolic volume (EDV) measured by echocardiography showed good correlation and agreement using either Simpson's method (r = 0.90; mean difference −2, 95% CI −47 to 43 mL) or Cylinder-hemiellipsoid method (r = 0.94; mean difference 3, 95% CI −44 to 49 mL). Furthermore, End-systolic volume (ESV) measured by echocardiography showed also good correlation and agreement using either Simpson's method (r = 0.94; mean difference 12 ml, 95% CI: −16 to 40) or Cylinder-hemiellipsoid methodAbstract Background We evaluated echocardiographic area-length methods to measure left ventricle (LV) volumes and ejection fraction (EF) in parasternal short axis views in comparison with cardiac computed tomography (CT) in pigs with chronic myocardial infarction (MI). Methods Male farm pigs with surgical occlusion of the left anterior descending coronary artery (n = 9) or sham operation (n = 5) had transthoracic echocardiography and cardiac-CT 3 months after surgery. We measured length of the LV in parasternal long axis view, and both systolic and diastolic LV areas in parasternal short axis views at the level of mitral valve, papillary muscles and apex. Volumes and EF of the LV were calculated using Simpson's method of discs (tri-plane area) or Cylinder-hemiellipsoid method (single plane area). Results The pigs with coronary occlusion had anterior MI scars and reduced EF (average EF 42 ± 10%) by CT. Measurements of LV volumes and EF were reproducible by echocardiography. Compared with CT, end-diastolic volume (EDV) measured by echocardiography showed good correlation and agreement using either Simpson's method (r = 0.90; mean difference −2, 95% CI −47 to 43 mL) or Cylinder-hemiellipsoid method (r = 0.94; mean difference 3, 95% CI −44 to 49 mL). Furthermore, End-systolic volume (ESV) measured by echocardiography showed also good correlation and agreement using either Simpson's method (r = 0.94; mean difference 12 ml, 95% CI: −16 to 40) or Cylinder-hemiellipsoid method (r = 0.97; mean difference:13 ml, 95% CI: −8 to 33). EF was underestimated using either Simpson's method (r = 0.78; mean difference −6, 95% CI −11 to 1%) or Cylinder-hemiellipsoid method (r = 0.74; mean difference −4, 95% CI–10 to 2%). Conclusion Our results indicate that measurement of LV volumes may be accurate, but EF is underestimated using either three or single parasternal short axis planes by echocardiography in a large animal model of chronic MI. … (more)
- Is Part Of:
- Cardiovascular ultrasound. Volume 15:Issue 1(2017)
- Journal:
- Cardiovascular ultrasound
- Issue:
- Volume 15:Issue 1(2017)
- Issue Display:
- Volume 15, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2017-0015-0001-0000
- Page Start:
- 1
- Page End:
- 9
- Publication Date:
- 2017-12
- Subjects:
- Ejection fraction -- Transthoracic echocardiography -- Cardiac CT
Echocardiography -- Periodicals
Intravascular ultrasonography -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
616.1207543 - Journal URLs:
- http://www.cardiovascularultrasound.com/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=195 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12947-016-0093-0 ↗
- Languages:
- English
- ISSNs:
- 1476-7120
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10061.xml