Barsheshet, Alon - Abstract:
- Abstract Aims There are limited data regarding the effect of diabetes mellitus (DM) on the risks of both appropriate and inappropriate implantable cardioverter defibrillator (ICD) therapy. The present study was designed to compare the outcome of appropriate and inappropriate ICD therapy in patients with or without DM. Methods and results The risk of a first appropriate ICD therapy for ventricular tachyarrhythmias (including anti tachycardia pacing and shock) was compared between 764 DM and 1346 non-DM patients enrolled in the national Israeli ICD registry. We also compared the risks of inappropriate ICD therapy, and death or cardiac hospitalization between diabetic and non-diabetic patients. Diabetic patients were older, were more likely to have ischemic cardiomyopathy, lower ejection fraction, atrial fibrillation, and other co-morbidities. The 3-year cumulative incidence of appropriate ICD therapy was similar in the DM and non-DM groups (12 and 13%, respectively, p = 0.983). Multivariate analysis showed that DM did not affect the risk of appropriate ICD therapy (HR = 1.07, 95% CI 0.78–1.47, p = 0.694) or inappropriate therapy (HR = 0.72, 95% CI 0.42–1.23, p = 0.232). However, DM was associated with a 31% increased risk for death or cardiac hospitalization (p = 0.005). Results were similar in subgroup analyses including ICD and defibrillators with cardiac resynchronization therapy function recipients, primary or secondary prevention indication for an ICD. Conclusions DespiteAbstract Aims There are limited data regarding the effect of diabetes mellitus (DM) on the risks of both appropriate and inappropriate implantable cardioverter defibrillator (ICD) therapy. The present study was designed to compare the outcome of appropriate and inappropriate ICD therapy in patients with or without DM. Methods and results The risk of a first appropriate ICD therapy for ventricular tachyarrhythmias (including anti tachycardia pacing and shock) was compared between 764 DM and 1346 non-DM patients enrolled in the national Israeli ICD registry. We also compared the risks of inappropriate ICD therapy, and death or cardiac hospitalization between diabetic and non-diabetic patients. Diabetic patients were older, were more likely to have ischemic cardiomyopathy, lower ejection fraction, atrial fibrillation, and other co-morbidities. The 3-year cumulative incidence of appropriate ICD therapy was similar in the DM and non-DM groups (12 and 13%, respectively, p = 0.983). Multivariate analysis showed that DM did not affect the risk of appropriate ICD therapy (HR = 1.07, 95% CI 0.78–1.47, p = 0.694) or inappropriate therapy (HR = 0.72, 95% CI 0.42–1.23, p = 0.232). However, DM was associated with a 31% increased risk for death or cardiac hospitalization (p = 0.005). Results were similar in subgroup analyses including ICD and defibrillators with cardiac resynchronization therapy function recipients, primary or secondary prevention indication for an ICD. Conclusions Despite a significant excess of cardiac hospitalizations and mortality in the diabetic population, there was no difference in the rate of ICD treatments, suggesting that the outcome difference is not related to arrhythmias. … (more)
- Is Part Of:
- Cardiovascular diabetology. Volume 15:Issue 1(2016)
- Journal:
- Cardiovascular diabetology
- Issue:
- Volume 15:Issue 1(2016)
- Issue Display:
- Volume 15, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2016-0015-0001-0000
- Page Start:
- 1
- Page End:
- 6
- Publication Date:
- 2016-12
- Subjects:
- Implantable cardioverter defibrillator -- Diabetes mellitus -- Heart failure -- Outcomes
Diabetes -- Complications -- Periodicals
Cardiovascular system -- Diseases -- Complications -- Periodicals
Cardiovascular system -- Diseases -- Prevention -- Periodicals
616.462 - Journal URLs:
- http://www.biomedcentral.com/1475-2840 ↗
http://www.cardiab.com/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=107 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12933-016-0478-2 ↗
- Languages:
- English
- ISSNs:
- 1475-2840
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10056.xml