Time–Motion Analysis of Nurses Utilizing Insulin Pen Devices Compared to Vial and Syringe in an Inpatient Setting. (April 2019)
- Record Type:
- Journal Article
- Title:
- Time–Motion Analysis of Nurses Utilizing Insulin Pen Devices Compared to Vial and Syringe in an Inpatient Setting. (April 2019)
- Main Title:
- Time–Motion Analysis of Nurses Utilizing Insulin Pen Devices Compared to Vial and Syringe in an Inpatient Setting
- Authors:
- Shogbon-Nwaesei, Angela O.
Jacob, Bobby C.
Kimble, Laura P.
Peasah, Samuel K.
Burtner, Joan
Moody, Laura
Ngo, Dao
Ryan, Gina - Other Names:
- Millares-Sipin Catherine A. guest-editor.
- Abstract:
- Objective: To compare the time taken and steps completed by nurses in the process of insulin preparation and administration using the pen device compared to the vial and syringe method. Methods: Observational and exploratory study utilizing a time–motion analysis of nurses' administration of insulin using the pen versus vial and syringe delivery methods. Nurses were observed, video-recorded, and timed during insulin preparation and administration using each delivery method. The steps performed by nurses were observed against recommended processes for preparing and administering insulin, and the percentage of nurses completing each step was noted. Results: A total of 137 (94%) nurses participated. Nurses took less time preparing and administering insulin with the pen device compared with the vial and syringe method (79 ± 18 seconds vs 88 ± 20 seconds, respectively, P < .001). The overall average completion rate of steps with the pen device was 90% ± 7% compared to 88% ± 7% with the vial and syringe method. Conclusion: The time taken by nurses to prepare and administer insulin was lower with the pen device compared with vial and syringe. Furthermore, areas were identified for potential nursing education to enhance safe and appropriate use of insulin with both delivery methods.
- Is Part Of:
- Journal of pharmacy practice. Volume 32:Number 2(2019:Apr.)
- Journal:
- Journal of pharmacy practice
- Issue:
- Volume 32:Number 2(2019:Apr.)
- Issue Display:
- Volume 32, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2019-0032-0002-0000
- Page Start:
- 126
- Page End:
- 131
- Publication Date:
- 2019-04
- Subjects:
- time–motion analysis -- nursing time -- insulin pens -- insulin vial and syringes -- inpatient
Pharmacy -- Periodicals
Pharmacology -- Periodicals
615.1 - Journal URLs:
- http://jpp.sagepub.com ↗
http://www.sagepublications.com/ ↗ - DOI:
- 10.1177/0897190017743132 ↗
- Languages:
- English
- ISSNs:
- 0897-1900
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10047.xml