Hemodynamic analysis of sequential graft from right coronary system to left coronary system. Issue 2 (December 2016)
- Record Type:
- Journal Article
- Title:
- Hemodynamic analysis of sequential graft from right coronary system to left coronary system. Issue 2 (December 2016)
- Main Title:
- Hemodynamic analysis of sequential graft from right coronary system to left coronary system
- Authors:
- Wang, Wenxin
Mao, Boyan
Wang, Haoran
Geng, Xueying
Zhao, Xi
Zhang, Huixia
Xie, Jinsheng
Zhao, Zhou
Lian, Bo
Liu, Youjun - Abstract:
- Abstract Background Sequential and single grafting are two surgical procedures of coronary artery bypass grafting. However, it remains unclear if the sequential graft can be used between the right and left coronary artery system. The purpose of this paper is to clarify the possibility of right coronary artery system anastomosis to left coronary system. Methods A patient-specific 3D model was first reconstructed based on coronary computed tomography angiography (CCTA) images. Two different grafts, the normal multi-graft (Model 1) and the novel multi-graft (Model 2), were then implemented on this patient-specific model using virtual surgery techniques. In Model 1, the single graft was anastomosed to right coronary artery (RCA) and the sequential graft was adopted to anastomose left anterior descending (LAD) and left circumflex artery (LCX). While in Model 2, the single graft was anastomosed to LAD and the sequential graft was adopted to anastomose RCA and LCX. A zero-dimensional/three-dimensional (0D/3D) coupling method was used to realize the multi-scale simulation of both the pre-operative and two post-operative models. Results Flow rates in the coronary artery and grafts were obtained. The hemodynamic parameters were also showed, including wall shear stress (WSS) and oscillatory shear index (OSI). The area of low WSS and OSI in Model 1 was much less than that in Model 2. Conclusions Model 1 shows optimistic hemodynamic modifications which may enhance the long-term patencyAbstract Background Sequential and single grafting are two surgical procedures of coronary artery bypass grafting. However, it remains unclear if the sequential graft can be used between the right and left coronary artery system. The purpose of this paper is to clarify the possibility of right coronary artery system anastomosis to left coronary system. Methods A patient-specific 3D model was first reconstructed based on coronary computed tomography angiography (CCTA) images. Two different grafts, the normal multi-graft (Model 1) and the novel multi-graft (Model 2), were then implemented on this patient-specific model using virtual surgery techniques. In Model 1, the single graft was anastomosed to right coronary artery (RCA) and the sequential graft was adopted to anastomose left anterior descending (LAD) and left circumflex artery (LCX). While in Model 2, the single graft was anastomosed to LAD and the sequential graft was adopted to anastomose RCA and LCX. A zero-dimensional/three-dimensional (0D/3D) coupling method was used to realize the multi-scale simulation of both the pre-operative and two post-operative models. Results Flow rates in the coronary artery and grafts were obtained. The hemodynamic parameters were also showed, including wall shear stress (WSS) and oscillatory shear index (OSI). The area of low WSS and OSI in Model 1 was much less than that in Model 2. Conclusions Model 1 shows optimistic hemodynamic modifications which may enhance the long-term patency of grafts. The anterior segments of sequential graft have better long-term patency than the posterior segments. With rational spatial position of the heart vessels, the last anastomosis of sequential graft should be connected to the main branch. … (more)
- Is Part Of:
- Biomedical engineering online. Volume 15:Issue 2(2016)
- Journal:
- Biomedical engineering online
- Issue:
- Volume 15:Issue 2(2016)
- Issue Display:
- Volume 15, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 15
- Issue:
- 2
- Issue Sort Value:
- 2016-0015-0002-0000
- Page Start:
- 545
- Page End:
- 556
- Publication Date:
- 2016-12
- Subjects:
- Hemodynamics -- Multi-branch -- Sequential graft -- Computational fluid dynamic (CFD)
Biomedical engineering -- Periodicals
610.2805 - Journal URLs:
- http://www.biomedical-engineering-online.com/> ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=106&action=archive ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12938-016-0259-x ↗
- Languages:
- English
- ISSNs:
- 1475-925X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10050.xml