Evaluation of pulmonary and systemic toxicity following lung exposure to graphite nanoplates: a member of the graphene-based nanomaterial family. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of pulmonary and systemic toxicity following lung exposure to graphite nanoplates: a member of the graphene-based nanomaterial family. Issue 1 (December 2015)
- Main Title:
- Evaluation of pulmonary and systemic toxicity following lung exposure to graphite nanoplates: a member of the graphene-based nanomaterial family
- Authors:
- Roberts, Jenny
Mercer, Robert
Stefaniak, Aleksandr
Seehra, Mohindar
Geddam, Usha
Chaudhuri, Ishrat
Kyrlidis, Angelos
Kodali, Vamsi
Sager, Tina
Kenyon, Allison
Bilgesu, Suzan
Eye, Tracy
Scabilloni, James
Leonard, Stephen
Fix, Natalie
Schwegler-Berry, Diane
Farris, Breanne
Wolfarth, Michael
Porter, Dale
Castranova, Vincent
Erdely, Aaron - Abstract:
- Abstract Background Graphene, a monolayer of carbon, is an engineered nanomaterial (ENM) with physical and chemical properties that may offer application advantages over other carbonaceous ENMs, such as carbon nanotubes (CNT). The goal of this study was to comparatively assess pulmonary and systemic toxicity of graphite nanoplates, a member of the graphene-based nanomaterial family, with respect to nanoplate size. Methods Three sizes of graphite nanoplates [20 μm lateral (Gr20), 5 μm lateral (Gr5), and <2 μm lateral (Gr1)] ranging from 8–25 nm in thickness were characterized for difference in surface area, structure, , zeta potential, and agglomeration in dispersion medium, the vehicle for in vivo studies. Mice were exposed by pharyngeal aspiration to these 3 sizes of graphite nanoplates at doses of 4 or 40 μg/mouse, or to carbon black (CB) as a carbonaceous control material. At 4 h, 1 day, 7 days, 1 month, and 2 months post-exposure, bronchoalveolar lavage was performed to collect fluid and cells for analysis of lung injury and inflammation. Particle clearance, histopathology and gene expression in lung tissue were evaluated. In addition, protein levels and gene expression were measured in blood, heart, aorta and liver to assess systemic responses. Results All Gr samples were found to be similarly composed of two graphite structures and agglomerated to varying degrees in DM in proportion to the lateral dimension. Surface area for Gr1 was approximately 7-fold greater thanAbstract Background Graphene, a monolayer of carbon, is an engineered nanomaterial (ENM) with physical and chemical properties that may offer application advantages over other carbonaceous ENMs, such as carbon nanotubes (CNT). The goal of this study was to comparatively assess pulmonary and systemic toxicity of graphite nanoplates, a member of the graphene-based nanomaterial family, with respect to nanoplate size. Methods Three sizes of graphite nanoplates [20 μm lateral (Gr20), 5 μm lateral (Gr5), and <2 μm lateral (Gr1)] ranging from 8–25 nm in thickness were characterized for difference in surface area, structure, , zeta potential, and agglomeration in dispersion medium, the vehicle for in vivo studies. Mice were exposed by pharyngeal aspiration to these 3 sizes of graphite nanoplates at doses of 4 or 40 μg/mouse, or to carbon black (CB) as a carbonaceous control material. At 4 h, 1 day, 7 days, 1 month, and 2 months post-exposure, bronchoalveolar lavage was performed to collect fluid and cells for analysis of lung injury and inflammation. Particle clearance, histopathology and gene expression in lung tissue were evaluated. In addition, protein levels and gene expression were measured in blood, heart, aorta and liver to assess systemic responses. Results All Gr samples were found to be similarly composed of two graphite structures and agglomerated to varying degrees in DM in proportion to the lateral dimension. Surface area for Gr1 was approximately 7-fold greater than Gr5 and Gr20, but was less reactive reactive per m2 . At the low dose, none of the Gr materials induced toxicity. At the high dose, Gr20 and Gr5 exposure increased indices of lung inflammation and injury in lavage fluid and tissue gene expression to a greater degree and duration than Gr1 and CB. Gr5 and Gr20 showed no or minimal lung epithelial hypertrophy and hyperplasia, and no development of fibrosis by 2 months post-exposure. In addition, the aorta and liver inflammatory and acute phase genes were transiently elevated in Gr5 and Gr20, relative to Gr1. Conclusions Pulmonary and systemic toxicity of graphite nanoplates may be dependent on lateral size and/or surface reactivity, with the graphite nanoplates > 5 μm laterally inducing greater toxicity which peaked at the early time points post-exposure relative to the 1–2 μm graphite nanoplate. … (more)
- Is Part Of:
- Particle and fibre toxicology. Volume 13:Issue 1(2016)
- Journal:
- Particle and fibre toxicology
- Issue:
- Volume 13:Issue 1(2016)
- Issue Display:
- Volume 13, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 13
- Issue:
- 1
- Issue Sort Value:
- 2016-0013-0001-0000
- Page Start:
- 1
- Page End:
- 22
- Publication Date:
- 2015-12
- Subjects:
- Graphene-based nanomaterials -- Pulmonary exposure -- Cardiovascular toxicity -- Lung toxicity -- Particle size
Particles -- Toxicology -- Periodicals
Fibers -- Toxicology -- Periodicals
615.9 - Journal URLs:
- http://particleandfibretoxicology.biomedcentral.com/ ↗
http://pubmedcentral.com/tocrender.fcgi?journal=305 ↗
http://www.particleandfibretoxicology.com/home/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12989-016-0145-5 ↗
- Languages:
- English
- ISSNs:
- 1743-8977
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10035.xml