Accuracy of gadoteridol enhanced MR-angiography in the evaluation of carotid artery stenosis. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Accuracy of gadoteridol enhanced MR-angiography in the evaluation of carotid artery stenosis. Issue 1 (December 2015)
- Main Title:
- Accuracy of gadoteridol enhanced MR-angiography in the evaluation of carotid artery stenosis
- Authors:
- Zaccagna, Fulvio
Sacconi, Beatrice
Saba, Luca
Ceravolo, Isabella
Fiorelli, Andrea
Carbone, Iacopo
Napoli, Alessandro
Anzidei, Michele
Catalano, Carlo - Abstract:
- Abstract Background To compare image quality and diagnostic performance of Gadoteridol-enhanced MR angiography (MRA) with Gadobutrol-enhanced MRA in the evaluation of carotid artery stenosis. Methods MRA was performed in 30 patients with carotid stenosis diagnosed at DUS. Patients were randomly assigned to group A (Gadobutrol-enhanced MRA) or group B (Gadoteridol-enhanced MRA). All examinations were performed with a 3T MR system. Image quality was assessed qualitatively by a 3-grade scale and quantitatively with SNR measurements. Diagnostic performance in the assessment of stenosis, plaque length and morphology was evaluated in the two MRA groups by accuracy calculation and RoC curves analysis using CTA as reference standard. Statistically significant differences in SNR and quality scale were evaluated by the Independent-Samples T Test and Mann–Whitney test, while the Z-statistics was used to compare diagnostic accuracy in the two groups. Results Image quality was graded adequate to excellent for both GBCAs, without significant differences (p = 0.165). SNR values were not significantly different in group B (Gadoteridol-enhanced MRA) as compared to group A (Gadobutrol-enhanced MRA) (89.32 ± 70.4 vs 81.09 ± 28.38;p = 0.635). Diagnostic accuracy was 94 % for the evaluation of stenosis degree and 94 % for the identification of ulcerated plaques in group A, while it was 93 % for the evaluation of stenosis degree and 76 % for the identification of ulcerated plaques in group B,Abstract Background To compare image quality and diagnostic performance of Gadoteridol-enhanced MR angiography (MRA) with Gadobutrol-enhanced MRA in the evaluation of carotid artery stenosis. Methods MRA was performed in 30 patients with carotid stenosis diagnosed at DUS. Patients were randomly assigned to group A (Gadobutrol-enhanced MRA) or group B (Gadoteridol-enhanced MRA). All examinations were performed with a 3T MR system. Image quality was assessed qualitatively by a 3-grade scale and quantitatively with SNR measurements. Diagnostic performance in the assessment of stenosis, plaque length and morphology was evaluated in the two MRA groups by accuracy calculation and RoC curves analysis using CTA as reference standard. Statistically significant differences in SNR and quality scale were evaluated by the Independent-Samples T Test and Mann–Whitney test, while the Z-statistics was used to compare diagnostic accuracy in the two groups. Results Image quality was graded adequate to excellent for both GBCAs, without significant differences (p = 0.165). SNR values were not significantly different in group B (Gadoteridol-enhanced MRA) as compared to group A (Gadobutrol-enhanced MRA) (89.32 ± 70.4 vs 81.09 ± 28.38;p = 0.635). Diagnostic accuracy was 94 % for the evaluation of stenosis degree and 94 % for the identification of ulcerated plaques in group A, while it was 93 % for the evaluation of stenosis degree and 76 % for the identification of ulcerated plaques in group B, without statistically significant differences (p = 0.936). Conclusion No significant difference in terms of image quality and diagnostic accuracy was observed between Gadoteridol-enhanced MRA and Gadobutrol-enhanced MRA in patients undergoing evaluation of carotid stenosis. … (more)
- Is Part Of:
- Neurovascular imaging. Volume 1:Issue 1(2015)
- Journal:
- Neurovascular imaging
- Issue:
- Volume 1:Issue 1(2015)
- Issue Display:
- Volume 1, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 1
- Issue:
- 1
- Issue Sort Value:
- 2015-0001-0001-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2015-12
- Subjects:
- Neurovascular diseases -- Magnetic resonance imaging -- Periodicals
Neurovascular diseases -- Radiography -- Periodicals
616.807548 - Journal URLs:
- http://www.nvijournal.com/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s40809-015-0009-7 ↗
- Languages:
- English
- ISSNs:
- 2055-5792
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10034.xml