The safe screw path along inferior border of the arcuate line at acetabular area: an anatomical study based on CT scans. Issue 1 (December 2017)
- Record Type:
- Journal Article
- Title:
- The safe screw path along inferior border of the arcuate line at acetabular area: an anatomical study based on CT scans. Issue 1 (December 2017)
- Main Title:
- The safe screw path along inferior border of the arcuate line at acetabular area: an anatomical study based on CT scans
- Authors:
- Bi, Chun
Wang, Jiandong
Ji, Xiaoxi
Ma, Zhijian
Wang, Fang
Zeng, Xiangsen
Wang, Dongmei
Wang, Qiugen - Abstract:
- Abstract Background Misplaced screw during the internal fixation of acetabular fractures may penetrate the hip joint which might cause chondrolysis and traumatic osteoarthritis in the future. This study aims to acquire the safe path for screw insertion along inferior border of the arcuate line fixation route at acetabular area. Methods Computed tomography (CT) scans of 98 patients without pelvic trauma were rebuilt for three-dimensional models of pelvis. After depicting the fixation route curve, five cross-sections perpendicularly to the curve were established from the anterior of pelvis to the posterior along inferior border of the arcuate line. The safe screw lengths for section 1 and 5 were measured from the computer models. In section 2, 3 and 4, a line from the screw entry point tangent to the inferior edge of the acetabulum was depicted and the measurements of minimum safe direction of screw insertion were performed then marked with angle θ. Results The safe screw lengths for section 1 and 5 were 22.29 ± 4.41 mm and 32.64 ± 4.70 mm (n = 98). The minimum safe angles of screw insertion for the middle three sections 2, 3, and 4 were 65.38 ± 10.23°, 74.20 ± 10.20°, and 57.88 ± 11.11°(n = 98), respectively. The results for the male group (n = 98) indicated smaller minimum safe angles in these three sections compared with the female (n = 98). Conclusions Compared to male, the minimum safe angles of screw placement at acetabular area for female should be more away fromAbstract Background Misplaced screw during the internal fixation of acetabular fractures may penetrate the hip joint which might cause chondrolysis and traumatic osteoarthritis in the future. This study aims to acquire the safe path for screw insertion along inferior border of the arcuate line fixation route at acetabular area. Methods Computed tomography (CT) scans of 98 patients without pelvic trauma were rebuilt for three-dimensional models of pelvis. After depicting the fixation route curve, five cross-sections perpendicularly to the curve were established from the anterior of pelvis to the posterior along inferior border of the arcuate line. The safe screw lengths for section 1 and 5 were measured from the computer models. In section 2, 3 and 4, a line from the screw entry point tangent to the inferior edge of the acetabulum was depicted and the measurements of minimum safe direction of screw insertion were performed then marked with angle θ. Results The safe screw lengths for section 1 and 5 were 22.29 ± 4.41 mm and 32.64 ± 4.70 mm (n = 98). The minimum safe angles of screw insertion for the middle three sections 2, 3, and 4 were 65.38 ± 10.23°, 74.20 ± 10.20°, and 57.88 ± 11.11°(n = 98), respectively. The results for the male group (n = 98) indicated smaller minimum safe angles in these three sections compared with the female (n = 98). Conclusions Compared to male, the minimum safe angles of screw placement at acetabular area for female should be more away from inferior edge of acetabulum and tilt to the bottom of pelvis along inferior border fixation route in surgical management of acetabular fractures. … (more)
- Is Part Of:
- BMC musculoskeletal disorders. Volume 18:Issue 1(2017)
- Journal:
- BMC musculoskeletal disorders
- Issue:
- Volume 18:Issue 1(2017)
- Issue Display:
- Volume 18, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 18
- Issue:
- 1
- Issue Sort Value:
- 2017-0018-0001-0000
- Page Start:
- 1
- Page End:
- 6
- Publication Date:
- 2017-12
- Subjects:
- Digital anatomical measurement -- Acetabular fracture -- Safe screw insertion -- Inferior border of arcuate line
Musculoskeletal system -- Diseases -- Periodicals
616.705 - Journal URLs:
- http://www.biomedcentral.com/bmcmusculoskeletdisord/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=46 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12891-017-1453-0 ↗
- Languages:
- English
- ISSNs:
- 1471-2474
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10029.xml