Integrated strategy for in vitro characterization of a bileaflet mechanical aortic valve. Issue 1 (December 2017)
- Record Type:
- Journal Article
- Title:
- Integrated strategy for in vitro characterization of a bileaflet mechanical aortic valve. Issue 1 (December 2017)
- Main Title:
- Integrated strategy for in vitro characterization of a bileaflet mechanical aortic valve
- Authors:
- Susin, Francesca
Espa, Stefania
Toninato, Riccardo
Fortini, Stefania
Querzoli, Giorgio - Abstract:
- Abstract Background Haemodynamic performance of heart valve prosthesis can be defined as its ability to fully open and completely close during the cardiac cycle, neither overloading heart work nor damaging blood particles when passing through the valve. In this perspective, global and local flow parameters, valve dynamics and blood damage safety of the prosthesis, as well as their mutual interactions, have all to be accounted for when assessing the device functionality. Even though all these issues have been and continue to be widely investigated, they are not usually studied through an integrated approach yet, i.e. by analyzing them simultaneously and highlighting their connections. Results An in vitro test campaign of flow through a bileaflet mechanical heart valve (Sorin Slimline 25 mm) was performed in a suitably arranged pulsatile mock loop able to reproduce human systemic pressure and flow curves. The valve was placed in an elastic, transparent, and anatomically accurate model of healthy aorta, and tested under several pulsatile flow conditions. Global and local hydrodynamics measurements and leaflet dynamics were analysed focusing on correlations between flow characteristics and valve motion. The haemolysis index due to the valve was estimated according to a literature power law model and related to hydrodynamic conditions, and a correlation between the spatial distribution of experimental shear stress and pannus/thrombotic deposits on mechanical valves was suggested.Abstract Background Haemodynamic performance of heart valve prosthesis can be defined as its ability to fully open and completely close during the cardiac cycle, neither overloading heart work nor damaging blood particles when passing through the valve. In this perspective, global and local flow parameters, valve dynamics and blood damage safety of the prosthesis, as well as their mutual interactions, have all to be accounted for when assessing the device functionality. Even though all these issues have been and continue to be widely investigated, they are not usually studied through an integrated approach yet, i.e. by analyzing them simultaneously and highlighting their connections. Results An in vitro test campaign of flow through a bileaflet mechanical heart valve (Sorin Slimline 25 mm) was performed in a suitably arranged pulsatile mock loop able to reproduce human systemic pressure and flow curves. The valve was placed in an elastic, transparent, and anatomically accurate model of healthy aorta, and tested under several pulsatile flow conditions. Global and local hydrodynamics measurements and leaflet dynamics were analysed focusing on correlations between flow characteristics and valve motion. The haemolysis index due to the valve was estimated according to a literature power law model and related to hydrodynamic conditions, and a correlation between the spatial distribution of experimental shear stress and pannus/thrombotic deposits on mechanical valves was suggested. As main and general result, this study validates the potential of the integrated strategy for performance assessment of any prosthetic valve thanks to its capability of highlighting the complex interaction between the different physical mechanisms that govern transvalvular haemodynamics. Conclusions We have defined an in vitro procedure for a comprehensive analysis of aortic valve prosthesis performance; the rationale for this study was the belief that a proper and overall characterization of the device should be based on the simultaneous measurement of all different quantities of interest for haemodynamic performance and the analysis of their mutual interactions. … (more)
- Is Part Of:
- Biomedical engineering online. Volume 16:Issue 1(2017)
- Journal:
- Biomedical engineering online
- Issue:
- Volume 16:Issue 1(2017)
- Issue Display:
- Volume 16, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2017-0016-0001-0000
- Page Start:
- 1
- Page End:
- 14
- Publication Date:
- 2017-12
- Subjects:
- Pulse duplicator -- Image velocimetry -- Valve leaflets dynamics -- Haemolysis index
Biomedical engineering -- Periodicals
610.2805 - Journal URLs:
- http://www.biomedical-engineering-online.com/> ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=106&action=archive ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12938-017-0314-2 ↗
- Languages:
- English
- ISSNs:
- 1475-925X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10031.xml