Cardiovascular magnetic resonance myocardial feature tracking using a non-rigid, elastic image registration algorithm: assessment of variability in a real-life clinical setting. Issue 1 (December 2017)
- Record Type:
- Journal Article
- Title:
- Cardiovascular magnetic resonance myocardial feature tracking using a non-rigid, elastic image registration algorithm: assessment of variability in a real-life clinical setting. Issue 1 (December 2017)
- Main Title:
- Cardiovascular magnetic resonance myocardial feature tracking using a non-rigid, elastic image registration algorithm: assessment of variability in a real-life clinical setting
- Authors:
- Morais, Pedro
Marchi, Alberto
Bogaert, Julie
Dresselaers, Tom
Heyde, Brecht
D'hooge, Jan
Bogaert, Jan - Abstract:
- Abstract Background Cardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a promising technique for quantification of myocardial strain from steady-state free precession (SSFP) cine images. We sought to determine the variability of CMR-FT using a non-rigid elastic registration algorithm recently available in a commercial software package (Segment, Medviso) in a real-life clinical setting. Methods Firstly, we studied the variability in a healthy volunteer who underwent 10 CMR studies over five consecutive days. Secondly, 10 patients were selected from our CMR database yielding normal findings (normal group ). Finally, we prospectively studied 10 patients with known or suspected myocardial pathology referred for further investigation to CMR (patient group ). In the patient group a second study was performed respecting an interval of 30 min between studies. All studies were manually segmented at the end-diastolic phase by three observers. In all subjects left ventricular (LV) circumferential and radial strain were calculated in the short-axis direction (EccSAX and ErrSAX, respectively) and longitudinal strain in the long-axis direction (EllLAX ). The level of CMR experience of the observers was 2 weeks, 6 months and >20 years. Results Mean contouring time was 7 ± 1 min, mean FT calculation time 13 ± 2 min. Intra- and inter-observer variability was good to excellent with an coefficient of reproducibility (CR) ranging 1.6% to 11.5%, and 1.7% to 16.0%,Abstract Background Cardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a promising technique for quantification of myocardial strain from steady-state free precession (SSFP) cine images. We sought to determine the variability of CMR-FT using a non-rigid elastic registration algorithm recently available in a commercial software package (Segment, Medviso) in a real-life clinical setting. Methods Firstly, we studied the variability in a healthy volunteer who underwent 10 CMR studies over five consecutive days. Secondly, 10 patients were selected from our CMR database yielding normal findings (normal group ). Finally, we prospectively studied 10 patients with known or suspected myocardial pathology referred for further investigation to CMR (patient group ). In the patient group a second study was performed respecting an interval of 30 min between studies. All studies were manually segmented at the end-diastolic phase by three observers. In all subjects left ventricular (LV) circumferential and radial strain were calculated in the short-axis direction (EccSAX and ErrSAX, respectively) and longitudinal strain in the long-axis direction (EllLAX ). The level of CMR experience of the observers was 2 weeks, 6 months and >20 years. Results Mean contouring time was 7 ± 1 min, mean FT calculation time 13 ± 2 min. Intra- and inter-observer variability was good to excellent with an coefficient of reproducibility (CR) ranging 1.6% to 11.5%, and 1.7% to 16.0%, respectively and an intraclass correlation coefficient (ICC) ranging 0.89 to 1.00 and 0.74 to 0.99, respectively. Variability considerably increased in the test-retest setting with a CR ranging 4.2% to 29.1% and an ICC ranging 0.66 to 0.95 in the patient group. Variability was not influenced by level of expertise of the observers. Neither did the presence of myocardial pathology at CMR negatively impact variability. However, compared to global myocardial strain, segmental myocardial strain variability increased with a factor 2–3, in particular for the basal and apical short-axis slices. Conclusions CMR-FT using non-rigid, elastic registration is a reproducible approach for strain analysis in patients routinely scheduled for CMR, and is not influenced by the level of training. However, further improvement is needed to reliably depict small variations in segmental myocardial strain. … (more)
- Is Part Of:
- Journal of cardiovascular magnetic resonance. Volume 19:Issue 1(2017)
- Journal:
- Journal of cardiovascular magnetic resonance
- Issue:
- Volume 19:Issue 1(2017)
- Issue Display:
- Volume 19, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 19
- Issue:
- 1
- Issue Sort Value:
- 2017-0019-0001-0000
- Page Start:
- 1
- Page End:
- 13
- Publication Date:
- 2017-12
- Subjects:
- Cardiovascular system -- Magnetic resonance imaging -- Periodicals
616.1207548 - Journal URLs:
- http://jcmr-online.com/ ↗
http://www.informaworld.com/1532-429X ↗
http://www.tandfonline.com/ ↗
http://www.dekker.com/servlet/product/productid/JCMR ↗ - DOI:
- 10.1186/s12968-017-0333-y ↗
- Languages:
- English
- ISSNs:
- 1097-6647
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866600
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10025.xml