Measurement of axial vertebral rotation using three-dimensional ultrasound images. Issue 2 (December 2015)
- Record Type:
- Journal Article
- Title:
- Measurement of axial vertebral rotation using three-dimensional ultrasound images. Issue 2 (December 2015)
- Main Title:
- Measurement of axial vertebral rotation using three-dimensional ultrasound images
- Authors:
- Vo, Quang
Lou, Edmond
Le, Lawrence - Abstract:
- Abstract Background Axial vertebral rotation (AVR) is one of the important parameters to evaluate the severity and predict the progression of scoliosis. However, the AVR measurements on radiographs may underestimate its actual value. This pilot study investigated a new three-dimensional (3D) ultrasound method to measure AVR. Methods Three cadaveric vertebrae T7, L1, and L3 were scanned with a 3D medical ultrasound system. Nine sets of ultrasound data, the vertebral rotation from 0 to 40° with 5° increments, were recorded from each vertebra. An in-house program was developed to reconstruct and measure the 3D vertebral images. The rotation of each reconstructed vertebra was determined by the angle between the line going through the centres of either laminae (L-L) or transverse processes (TP-TP) and a reference vertical plane. Three raters measured the rotation in 3 sessions, in which they used the mouse pointer to select the L-L or TP-TP according to their knowledge of vertebral anatomy. The program detected the 3D coordinates of these points and calculated the AVR. The intra-class correlation coefficients (ICCs) were used to calculate the intra-reliability and inter-reliability. The mean absolute difference (MAD±SD) and the range of difference (RD) between the actual values and the average measurements of each rater were computed to evaluate the accuracy of methods. Results When rotation was greater than 30° for both L1 and L3, all raters found it difficult to determine oneAbstract Background Axial vertebral rotation (AVR) is one of the important parameters to evaluate the severity and predict the progression of scoliosis. However, the AVR measurements on radiographs may underestimate its actual value. This pilot study investigated a new three-dimensional (3D) ultrasound method to measure AVR. Methods Three cadaveric vertebrae T7, L1, and L3 were scanned with a 3D medical ultrasound system. Nine sets of ultrasound data, the vertebral rotation from 0 to 40° with 5° increments, were recorded from each vertebra. An in-house program was developed to reconstruct and measure the 3D vertebral images. The rotation of each reconstructed vertebra was determined by the angle between the line going through the centres of either laminae (L-L) or transverse processes (TP-TP) and a reference vertical plane. Three raters measured the rotation in 3 sessions, in which they used the mouse pointer to select the L-L or TP-TP according to their knowledge of vertebral anatomy. The program detected the 3D coordinates of these points and calculated the AVR. The intra-class correlation coefficients (ICCs) were used to calculate the intra-reliability and inter-reliability. The mean absolute difference (MAD±SD) and the range of difference (RD) between the actual values and the average measurements of each rater were computed to evaluate the accuracy of methods. Results When rotation was greater than 30° for both L1 and L3, all raters found it difficult to determine one of the lamina areas due to the lack of ultrasound information in an area behind the spinous process. Therefore, the corresponding measurements were excluded. The ICC values of the intra-reliability (L-L, TP-TP) for the three raters were (0.987, 0.991), (0.989, 0.998) and (0.997, 1.000), respectively; meanwhile, the inter-reliability were 0.991 for (L-L) and 0.992 for (TP-TP). All ICC values were greater than 0.98 indicating both methods were highly reliable. The MAD±SD values (L-L, TP-TP) for the three raters were (1.5±0.3°, 1.2±0.2°), (1.6±0.3°, 1.3±0.3°), and (1.7±0.5°, 0.9±0.2°), respectively. The RD (L-L, TP-TP) were (0-4.5°, 0-3.5°), (0-5.1°, 0-4.3°), and (0-5.1°, 0-2.8°) for the three raters, respectively. Conclusions The (L-L) and (TP-TP) methods could be used to measure AVR reliability from the 3D ultrasound images. … (more)
- Is Part Of:
- Scoliosis. Volume 10:Issue 2(2015)
- Journal:
- Scoliosis
- Issue:
- Volume 10:Issue 2(2015)
- Issue Display:
- Volume 10, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 10
- Issue:
- 2
- Issue Sort Value:
- 2015-0010-0002-0000
- Page Start:
- 1
- Page End:
- 4
- Publication Date:
- 2015-12
- Subjects:
- Scoliosis -- Periodicals
616.73 - Journal URLs:
- http://www.scoliosisjournal.com/ ↗
http://link.springer.com/ ↗
http://pubmedcentral.com/tocrender.fcgi?journal=413&action=archive ↗ - DOI:
- 10.1186/1748-7161-10-S2-S7 ↗
- Languages:
- English
- ISSNs:
- 1748-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10028.xml