Effect of cryopreservation on delineation of immune cell subpopulations in tumor specimens as determinated by multiparametric single cell mass cytometry analysis. (December 2017)
- Record Type:
- Journal Article
- Title:
- Effect of cryopreservation on delineation of immune cell subpopulations in tumor specimens as determinated by multiparametric single cell mass cytometry analysis. (December 2017)
- Main Title:
- Effect of cryopreservation on delineation of immune cell subpopulations in tumor specimens as determinated by multiparametric single cell mass cytometry analysis
- Authors:
- Kadić, Elma
Moniz, Raymond
Huo, Ying
Chi, An
Kariv, Ilona - Abstract:
- Abstract Background Comprehensive understanding of cellular immune subsets involved in regulation of tumor progression is central to the development of cancer immunotherapies. Single cell immunophenotyping has historically been accomplished by flow cytometry (FC) analysis, enabling the analysis of up to 18 markers. Recent advancements in mass cytometry (MC) have facilitated detection of over 50 markers, utilizing high resolving power of mass spectrometry (MS). This study examined an analytical and operational feasibility of MC for an in-depth immunophenotyping analysis of the tumor microenvironment, using the commercial CyTOF™ instrument, and further interrogated challenges in managing the integrity of tumor specimens. Results Initial longitudinal studies with frozen peripheral blood mononuclear cells (PBMCs) showed minimal MC inter-assay variability over nine independent runs. In addition, detection of common leukocyte lineage markers using MC and FC detection confirmed that these methodologies are comparable in cell subset identification. An advanced multiparametric MC analysis of 39 total markers enabled a comprehensive evaluation of cell surface marker expression in fresh and cryopreserved tumor samples. This comparative analysis revealed significant reduction of expression levels of multiple markers upon cryopreservation. Most notably myeloid derived suppressor cells (MDSC), defined by co-expression of CD66b+ and CD15+, HLA-DRdim and CD14− phenotype, were undetectableAbstract Background Comprehensive understanding of cellular immune subsets involved in regulation of tumor progression is central to the development of cancer immunotherapies. Single cell immunophenotyping has historically been accomplished by flow cytometry (FC) analysis, enabling the analysis of up to 18 markers. Recent advancements in mass cytometry (MC) have facilitated detection of over 50 markers, utilizing high resolving power of mass spectrometry (MS). This study examined an analytical and operational feasibility of MC for an in-depth immunophenotyping analysis of the tumor microenvironment, using the commercial CyTOF™ instrument, and further interrogated challenges in managing the integrity of tumor specimens. Results Initial longitudinal studies with frozen peripheral blood mononuclear cells (PBMCs) showed minimal MC inter-assay variability over nine independent runs. In addition, detection of common leukocyte lineage markers using MC and FC detection confirmed that these methodologies are comparable in cell subset identification. An advanced multiparametric MC analysis of 39 total markers enabled a comprehensive evaluation of cell surface marker expression in fresh and cryopreserved tumor samples. This comparative analysis revealed significant reduction of expression levels of multiple markers upon cryopreservation. Most notably myeloid derived suppressor cells (MDSC), defined by co-expression of CD66b+ and CD15+, HLA-DRdim and CD14− phenotype, were undetectable in frozen samples. Conclusion These results suggest that optimization and evaluation of cryopreservation protocols is necessary for accurate biomarker discovery in frozen tumor specimens. … (more)
- Is Part Of:
- BMC immunology. Volume 18:Number 1(2017)
- Journal:
- BMC immunology
- Issue:
- Volume 18:Number 1(2017)
- Issue Display:
- Volume 18, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 18
- Issue:
- 1
- Issue Sort Value:
- 2017-0018-0001-0000
- Page Start:
- 1
- Page End:
- 15
- Publication Date:
- 2017-12
- Subjects:
- Mass Cytometry (MC) -- CyTOF™ -- Flow cytometry (FC) -- Tumor samples -- Tumor microenvironment (TME) -- Tumor infiltrating lymphocytes (TILs) -- Immunophenotyping -- Cryopreservation -- ViSNE
Immunology -- Periodicals
Immune System -- Periodicals
Immunity -- Periodicals
Immune System Diseases -- Periodicals
Immunologic Techniques -- Periodicals
616.07905 - Journal URLs:
- http://www.biomedcentral.com/bmcimmunol/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=35 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12865-017-0192-1 ↗
- Languages:
- English
- ISSNs:
- 1471-2172
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10032.xml