Two-month longitudinal study of mechanical properties of absorbable sutures used in orthopedic surgery. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- Two-month longitudinal study of mechanical properties of absorbable sutures used in orthopedic surgery. Issue 1 (December 2016)
- Main Title:
- Two-month longitudinal study of mechanical properties of absorbable sutures used in orthopedic surgery
- Authors:
- Müller, Daniel
Snedeker, Jess
Meyer, Dominik - Abstract:
- Abstract Background This is the first study assessing the properties of large-diameter degradable sutures relevant for orthopedic applications over the course of in vitro incubation for 2 months. The data we present here provide guidance to the orthopedic surgeon in predicting the long-term performance of suture materials used everyday in surgical practice. Methods Five different absorbable (Vicryl, Maxon, Monocryl, PDS II, Vicryl rapide) and one non-absorbable (Ethibond) suture materials were tested. Measurements were made at five time points during the 56 days of incubation under physiological conditions (37.0 ± 0.02 °C; pH 7.4 ± 0.2). The following variables were recorded: load to failure, strain at maximal load as elongation normalized to original length, stiffness as the ratio of load to displacement on the linear proportion of the stress strain curve, and hysteresis as area under the curve of the stress strain curve. Results Vicryl was the strongest fiber on day 0 (195 N); however, by day 42, the tensile strength of the suture reduced to 14 N. Between days 14 and 28, PDS II (171 N) and Maxon (182 N) sustained the highest loads. Monocryl (p = 0.003) and Maxon (p < 0.001) showed an increasing strain with time, whereas Vicryl (p = 0.002) and Vicryl rapide (p = 0.007) revealed an increasing material stiffness. Furthermore, both Vicryl (p = 0.053) and Monocryl (p < 0.001) had an increasing hysteresis with ongoing degradation. Maxon, PDS II, and Ethibond showed stableAbstract Background This is the first study assessing the properties of large-diameter degradable sutures relevant for orthopedic applications over the course of in vitro incubation for 2 months. The data we present here provide guidance to the orthopedic surgeon in predicting the long-term performance of suture materials used everyday in surgical practice. Methods Five different absorbable (Vicryl, Maxon, Monocryl, PDS II, Vicryl rapide) and one non-absorbable (Ethibond) suture materials were tested. Measurements were made at five time points during the 56 days of incubation under physiological conditions (37.0 ± 0.02 °C; pH 7.4 ± 0.2). The following variables were recorded: load to failure, strain at maximal load as elongation normalized to original length, stiffness as the ratio of load to displacement on the linear proportion of the stress strain curve, and hysteresis as area under the curve of the stress strain curve. Results Vicryl was the strongest fiber on day 0 (195 N); however, by day 42, the tensile strength of the suture reduced to 14 N. Between days 14 and 28, PDS II (171 N) and Maxon (182 N) sustained the highest loads. Monocryl (p = 0.003) and Maxon (p < 0.001) showed an increasing strain with time, whereas Vicryl (p = 0.002) and Vicryl rapide (p = 0.007) revealed an increasing material stiffness. Furthermore, both Vicryl (p = 0.053) and Monocryl (p < 0.001) had an increasing hysteresis with ongoing degradation. Maxon, PDS II, and Ethibond showed stable material properties during the 2 months. Conclusions The three absorbable sutures Vicryl, PDS II, and Maxon could sustain higher loads during the first 2 weeks than the non-absorbable Ethibond. Unexpectedly, Maxon and PDS II maintained their elastic properties in spite of their proceeding degradation and loss of tensile strength. … (more)
- Is Part Of:
- Journal of orthopaedic surgery and research. Volume 11:Issue 1(2016)
- Journal:
- Journal of orthopaedic surgery and research
- Issue:
- Volume 11:Issue 1(2016)
- Issue Display:
- Volume 11, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 11
- Issue:
- 1
- Issue Sort Value:
- 2016-0011-0001-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2016-12
- Subjects:
- Suture -- Absorbable fiber -- Material properties -- Degradation -- In vitro -- Orthopedic surgery
Orthopedics -- Periodicals
Orthopedic surgery -- Periodicals
616.7005 - Journal URLs:
- http://www.josr-online.com ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s13018-016-0451-5 ↗
- Languages:
- English
- ISSNs:
- 1749-799X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10033.xml