Compared to X-ray, three-dimensional computed tomography measurement is a reproducible radiographic method for normal proximal humerus. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- Compared to X-ray, three-dimensional computed tomography measurement is a reproducible radiographic method for normal proximal humerus. Issue 1 (December 2016)
- Main Title:
- Compared to X-ray, three-dimensional computed tomography measurement is a reproducible radiographic method for normal proximal humerus
- Authors:
- Jia, Xiaoyang
Chen, Yanxi
Qiang, Minfei
Zhang, Kun
Li, Haobo
Jiang, Yuchen
Zhang, Yijie - Abstract:
- Abstract Background Accurate comprehension of the normal humeral morphology is crucial for anatomical reconstruction in shoulder arthroplasty. However, traditional morphological measurements for humerus were mainly based on cadaver and radiography. The purpose of this study was to provide a series of precise and repeatable parameters of the normal proximal humerus for arthroplasty, based on the three-dimensional (3-D) measurements. Methods Radiographic and 3-D computed tomography (CT) measurements of the proximal humerus were performed in a sample of 120 consecutive adults. Sex differences, two image modalities differences, and correlations of the parameters were evaluated. Intra- and inter-observer reproducibility was evaluated using intraclass correlation coefficients (ICCs). Results In the male group, all parameters except the neck-shaft angle of humerus, based on 3-D CT images, were greater than those in the female group (P < 0.05). All variables were significantly different between two image modalities (P < 0.05). In 3-D CT measurement, all parameters expect neck-shaft angle had correlation with each other (P < 0.001), particularly between two diameters of the humeral head (r = 0.907). All parameters in the 3-D CT measurement had excellent reproducibility (ICC range, 0.878 to 0.936) that was higher than those in the radiographs (ICC range, 0.741 to 0.858). Conclusions The present study suggested that 3-D CT was more reproducible than plain radiography in theAbstract Background Accurate comprehension of the normal humeral morphology is crucial for anatomical reconstruction in shoulder arthroplasty. However, traditional morphological measurements for humerus were mainly based on cadaver and radiography. The purpose of this study was to provide a series of precise and repeatable parameters of the normal proximal humerus for arthroplasty, based on the three-dimensional (3-D) measurements. Methods Radiographic and 3-D computed tomography (CT) measurements of the proximal humerus were performed in a sample of 120 consecutive adults. Sex differences, two image modalities differences, and correlations of the parameters were evaluated. Intra- and inter-observer reproducibility was evaluated using intraclass correlation coefficients (ICCs). Results In the male group, all parameters except the neck-shaft angle of humerus, based on 3-D CT images, were greater than those in the female group (P < 0.05). All variables were significantly different between two image modalities (P < 0.05). In 3-D CT measurement, all parameters expect neck-shaft angle had correlation with each other (P < 0.001), particularly between two diameters of the humeral head (r = 0.907). All parameters in the 3-D CT measurement had excellent reproducibility (ICC range, 0.878 to 0.936) that was higher than those in the radiographs (ICC range, 0.741 to 0.858). Conclusions The present study suggested that 3-D CT was more reproducible than plain radiography in the assessment of morphology of the normal proximal humerus. Therefore, this reproducible modality could be utilized in the preoperative planning. Our data could serve as an effective guideline for humeral component selection and improve the design of shoulder prosthesis. … (more)
- Is Part Of:
- Journal of orthopaedic surgery and research. Volume 11:Issue 1(2016)
- Journal:
- Journal of orthopaedic surgery and research
- Issue:
- Volume 11:Issue 1(2016)
- Issue Display:
- Volume 11, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 11
- Issue:
- 1
- Issue Sort Value:
- 2016-0011-0001-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2016-12
- Subjects:
- Three-dimensional -- Shoulder morphology -- Shoulder geometry -- Shoulder anatomy -- Measurement -- Computed tomography -- Computer-assisted
Orthopedics -- Periodicals
Orthopedic surgery -- Periodicals
616.7005 - Journal URLs:
- http://www.josr-online.com ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s13018-016-0417-7 ↗
- Languages:
- English
- ISSNs:
- 1749-799X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10032.xml