Dürselen, Lutz - Abstract:
- Abstract Background The Zweymüller stem design has proven long-term stability with a 20-year survival rate of over 90 %. Primary stability necessitates implant-bone micromotions below 150 μm, otherwise bony ingrowth is negatively influenced. Methods Using fresh paired human femurs, we investigated a modification of the Zweymüller-type stem design with reduced proximal lateral shoulder in reference to primary stability. Relative motion between the implant and the cortical bone as well as the irreversible implant migration was investigated under dynamic loading (100–1600 N) over 100, 000 cycles using miniature displacement transducers. Results Micromotions were below the critical threshold for both implants at all measurement points. Axial reversible and irreversible micromotions were not influenced by reducing the shoulder of the prosthesis. Resistance against rotational moments was less pronounced after reduction of the shoulder without statistical significant results. Conclusions Reducing the proximal shoulder of the Zweymüller-type stem design does not negatively influence axial stability but might negatively influence rotational stability. Even though, comparable results still suggest a reasonable resistance against rotational forces.
- Is Part Of:
- Journal of orthopaedic surgery and research. Volume 11:Issue 1(2016)
- Journal:
- Journal of orthopaedic surgery and research
- Issue:
- Volume 11:Issue 1(2016)
- Issue Display:
- Volume 11, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 11
- Issue:
- 1
- Issue Sort Value:
- 2016-0011-0001-0000
- Page Start:
- 1
- Page End:
- 6
- Publication Date:
- 2016-12
- Subjects:
- Total hip arthroplasty -- Primary stability -- Cadaver -- Stress -- Mechanical -- Micromotion
Orthopedics -- Periodicals
Orthopedic surgery -- Periodicals
616.7005 - Journal URLs:
- http://www.josr-online.com ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s13018-016-0410-1 ↗
- Languages:
- English
- ISSNs:
- 1749-799X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10032.xml