Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment. Issue 1 (December 2015)
- Main Title:
- Quantitative three-dimensional myocardial perfusion cardiovascular magnetic resonance with accurate two-dimensional arterial input function assessment
- Authors:
- Wissmann, Lukas
Niemann, Markus
Gotschy, Alexander
Manka, Robert
Kozerke, Sebastian - Abstract:
- Abstract Background Quantification of myocardial perfusion from first-pass cardiovascular magnetic resonance (CMR) images at high contrast agent (CA) dose requires separate acquisition of blood pool and myocardial tissue enhancement. In this study, a dual-sequence approach interleaving 2D imaging of the arterial input function with high-resolution 3D imaging for myocardial perfusion assessment is presented and validated for low and high CA dose. Methods A dual-sequence approach interleaving 2D imaging of the aortic root and 3D imaging of the whole left ventricle using highly acceleratedk-t PCA was implemented. Rest perfusion imaging was performed in ten healthy volunteers after administration of a Gadolinium-based CA at low (0.025 mmol/kg b.w.) and high dose (0.1 mmol/kg b.w.). Arterial input functions extracted from the 2D and 3D images were analysed for both doses. Myocardial contrast-to-noise ratios (CNR) were compared across volunteers and doses. Variations of myocardial perfusion estimates between volunteers and across myocardial territories were studied. Results High CA dose imaging resulted in strong non-linearity of the arterial input function in the 3D images at peak CA concentration, which was avoided when the input function was derived from the 2D images. Myocardial CNR was significantly increased at high dose compared to low dose, with a 2.6-fold mean CNR gain. Most robust myocardial blood flow estimation was achieved using the arterial input function extractedAbstract Background Quantification of myocardial perfusion from first-pass cardiovascular magnetic resonance (CMR) images at high contrast agent (CA) dose requires separate acquisition of blood pool and myocardial tissue enhancement. In this study, a dual-sequence approach interleaving 2D imaging of the arterial input function with high-resolution 3D imaging for myocardial perfusion assessment is presented and validated for low and high CA dose. Methods A dual-sequence approach interleaving 2D imaging of the aortic root and 3D imaging of the whole left ventricle using highly acceleratedk-t PCA was implemented. Rest perfusion imaging was performed in ten healthy volunteers after administration of a Gadolinium-based CA at low (0.025 mmol/kg b.w.) and high dose (0.1 mmol/kg b.w.). Arterial input functions extracted from the 2D and 3D images were analysed for both doses. Myocardial contrast-to-noise ratios (CNR) were compared across volunteers and doses. Variations of myocardial perfusion estimates between volunteers and across myocardial territories were studied. Results High CA dose imaging resulted in strong non-linearity of the arterial input function in the 3D images at peak CA concentration, which was avoided when the input function was derived from the 2D images. Myocardial CNR was significantly increased at high dose compared to low dose, with a 2.6-fold mean CNR gain. Most robust myocardial blood flow estimation was achieved using the arterial input function extracted from the 2D image at high CA dose. In this case, myocardial blood flow estimates varied by 24 % between volunteers and by 20 % between myocardial territories when analysed on a per-volunteer basis. Conclusion Interleaving 2D imaging for arterial input function assessment enables robust quantitative 3D myocardial perfusion imaging at high CA dose. … (more)
- Is Part Of:
- Journal of cardiovascular magnetic resonance. Volume 17:Issue 1(2015)
- Journal:
- Journal of cardiovascular magnetic resonance
- Issue:
- Volume 17:Issue 1(2015)
- Issue Display:
- Volume 17, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2015-0017-0001-0000
- Page Start:
- 1
- Page End:
- 11
- Publication Date:
- 2015-12
- Subjects:
- DCE-MRI -- First-pass myocardial perfusion imaging -- Arterial input function -- Myocardial blood flow estimates -- Dual-sequence imaging
Cardiovascular system -- Magnetic resonance imaging -- Periodicals
616.1207548 - Journal URLs:
- http://jcmr-online.com/ ↗
http://www.informaworld.com/1532-429X ↗
http://www.tandfonline.com/ ↗
http://www.dekker.com/servlet/product/productid/JCMR ↗ - DOI:
- 10.1186/s12968-015-0212-3 ↗
- Languages:
- English
- ISSNs:
- 1097-6647
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866600
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10033.xml