Assessment of the Access AMH assay as an automated, high-performance replacement for the AMH Generation II manual ELISA. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- Assessment of the Access AMH assay as an automated, high-performance replacement for the AMH Generation II manual ELISA. Issue 1 (December 2016)
- Main Title:
- Assessment of the Access AMH assay as an automated, high-performance replacement for the AMH Generation II manual ELISA
- Authors:
- Pearson, Kylie
Long, Matthew
Prasad, Josephine
Wu, Ye
Bonifacio, Michael - Abstract:
- Abstract Background The manual Generation II (Gen II) ELISA method used to measure Anti-Müllerian Hormone (AMH) from Beckman Coulter has recently been superseded by a fully automated AMH immunoassay. The aim of this study was to evaluate the performance of the Access AMH assay and directly compare it to the modified Gen II ELISA method. A secondary aim was to verify that the fertile age-related AMH range previously established using the Gen II ELISA could be used to interpret results from the new automated Access assay. Methods The precision, stability, linearity, measurement range and detection limits were determined using recombinant AMH and patient serum samples. Different diluents and their effects on AMH concentration were compared. A correlation study was performed on patient samples to compare the Access AMH assay to the ELISA method on the Access2 and DxI800 analysers. The fertile AMH range was verified by comparing the 10th, 50th and 90th percentile values from both methods obtained from 489 natural conception pregnant women. Results The Access AMH assay showed good performance across the measuring range for both intra-assay (CV 1.41–3.30 %) and inter-assay (CV 3.04–5.76 %) precision and acceptable sample stability. Dilution of the high concentration samples with the recommended diluent resulted in a small but significant downward shift in values. The assay was linear over the range of values recommended by the manufacturer, allowing for accurate reporting withinAbstract Background The manual Generation II (Gen II) ELISA method used to measure Anti-Müllerian Hormone (AMH) from Beckman Coulter has recently been superseded by a fully automated AMH immunoassay. The aim of this study was to evaluate the performance of the Access AMH assay and directly compare it to the modified Gen II ELISA method. A secondary aim was to verify that the fertile age-related AMH range previously established using the Gen II ELISA could be used to interpret results from the new automated Access assay. Methods The precision, stability, linearity, measurement range and detection limits were determined using recombinant AMH and patient serum samples. Different diluents and their effects on AMH concentration were compared. A correlation study was performed on patient samples to compare the Access AMH assay to the ELISA method on the Access2 and DxI800 analysers. The fertile AMH range was verified by comparing the 10th, 50th and 90th percentile values from both methods obtained from 489 natural conception pregnant women. Results The Access AMH assay showed good performance across the measuring range for both intra-assay (CV 1.41–3.30 %) and inter-assay (CV 3.04–5.76 %) precision and acceptable sample stability. Dilution of the high concentration samples with the recommended diluent resulted in a small but significant downward shift in values. The assay was linear over the range of values recommended by the manufacturer, allowing for accurate reporting within the reported range. The two assay types were highly correlated (R2 = 0.9822 and 0.9832 for Access2 and DxI800, respectively), and the differences observed between the Access2 and DxI800 analysers were within clinically acceptable ranges, indicating that the methods are interchangeable. Furthermore, we demonstrated that results from the published reference range for the Gen II ELISA correlate with those from the automated Access AMH assay. Conclusion Here, we verified the published performance of the Access AMH assay and showed excellent correlation with the Gen II ELISA method. Moreover, we validated this correlation by confirming that the results from a fertile AMH reference range established using the preceding Gen II ELISA are interchangeable with the new automated Access AMH assay. … (more)
- Is Part Of:
- Reproductive biology and endocrinology. Volume 14:Issue 1(2016)
- Journal:
- Reproductive biology and endocrinology
- Issue:
- Volume 14:Issue 1(2016)
- Issue Display:
- Volume 14, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 14
- Issue:
- 1
- Issue Sort Value:
- 2016-0014-0001-0000
- Page Start:
- 1
- Page End:
- 9
- Publication Date:
- 2016-12
- Subjects:
- Anti-Müllerian Hormone -- AMH -- Assay -- Immunoassay -- ELISA -- Beckman Coulter -- Automated -- Reference range
Reproduction -- Periodicals
Generative organs -- Pathophysiology -- Periodicals
Reproduction -- Endocrine aspects -- Periodicals
Endocrine glands -- Diseases -- Periodicals
Embryology -- Periodicals
571.8 - Journal URLs:
- http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=141 ↗
http://www.rbej.com/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12958-016-0143-3 ↗
- Languages:
- English
- ISSNs:
- 1477-7827
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9996.xml