Performance comparison of a new automated cuff pressure controller with currently available devices in both basic research and clinical settings. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- Performance comparison of a new automated cuff pressure controller with currently available devices in both basic research and clinical settings. Issue 1 (December 2016)
- Main Title:
- Performance comparison of a new automated cuff pressure controller with currently available devices in both basic research and clinical settings
- Authors:
- Michikoshi, Junichi
Matsumoto, Shigekiyo
Miyawaki, Hiroshi
Niu, Harushi
Seo, Katsuhiro
Yamamoto, Makoto
Tokunaga, Shu-ichi
Kitano, Takaaki - Abstract:
- Abstract Background The management of tracheal tube cuff pressure in patients receiving mechanical ventilation is important for the prevention of ventilator-associated pneumonia. Currently, cuff pressure is intermittently monitored with a pressure gauge and adjusted when necessary in a routine practice. However, this method results in wide variations in pressure, and adequate management is difficult due to the spontaneous release of air from the cuff, which reduces cuff pressure. In order to continuously maintain a uniform cuff pressure, we developed a new automated cuff pressure controller and compared its properties with existing devices. Methods The effectiveness of the new device was assessed with a model trachea/lung and tracheal tube by measuring cuff pressure while on mechanical ventilation. An electrically powered automatic cuff controller or manual cuff pressure control was used for comparison purposes. The effectiveness of the new device was also examined in patients receiving mechanical ventilation by continuously measuring cuff pressure for a 24-h period. Results Cuff pressure was uniformly maintained with the new device. Moreover, in the clinical setting, variation in pressure from the set pressure was minimal with both the new device and existing device, relative to the intermittent monitoring method. This suggests that, as with the existing device, uniform cuff pressure management is possible with the new device. Conclusions Our results demonstrate the abilityAbstract Background The management of tracheal tube cuff pressure in patients receiving mechanical ventilation is important for the prevention of ventilator-associated pneumonia. Currently, cuff pressure is intermittently monitored with a pressure gauge and adjusted when necessary in a routine practice. However, this method results in wide variations in pressure, and adequate management is difficult due to the spontaneous release of air from the cuff, which reduces cuff pressure. In order to continuously maintain a uniform cuff pressure, we developed a new automated cuff pressure controller and compared its properties with existing devices. Methods The effectiveness of the new device was assessed with a model trachea/lung and tracheal tube by measuring cuff pressure while on mechanical ventilation. An electrically powered automatic cuff controller or manual cuff pressure control was used for comparison purposes. The effectiveness of the new device was also examined in patients receiving mechanical ventilation by continuously measuring cuff pressure for a 24-h period. Results Cuff pressure was uniformly maintained with the new device. Moreover, in the clinical setting, variation in pressure from the set pressure was minimal with both the new device and existing device, relative to the intermittent monitoring method. This suggests that, as with the existing device, uniform cuff pressure management is possible with the new device. Conclusions Our results demonstrate the ability of the new cuff pressure controller to manage cuff pressure without the need of a power source, highlighting its potential utility in clinical settings. … (more)
- Is Part Of:
- Journal of intensive care. Volume 4:Issue 1(2016)
- Journal:
- Journal of intensive care
- Issue:
- Volume 4:Issue 1(2016)
- Issue Display:
- Volume 4, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 4
- Issue:
- 1
- Issue Sort Value:
- 2016-0004-0001-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2016-12
- Subjects:
- Airway management -- Mechanical ventilation -- Respiratory care -- Automated cuff pressure gauge -- Tracheal intubation -- Cuff pressure
Critical care medicine -- Periodicals
Intensive care units -- Periodicals
616.028 - Journal URLs:
- http://jintensivecare.biomedcentral.com/ ↗
http://www.jintensivecare.com/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s40560-016-0126-7 ↗
- Languages:
- English
- ISSNs:
- 2052-0492
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10018.xml