Systematic review of the validity and reliability of consumer-wearable activity trackers. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Systematic review of the validity and reliability of consumer-wearable activity trackers. Issue 1 (December 2015)
- Main Title:
- Systematic review of the validity and reliability of consumer-wearable activity trackers
- Authors:
- Evenson, Kelly
Goto, Michelle
Furberg, Robert - Abstract:
- Abstract Background Consumer-wearable activity trackers are electronic devices used for monitoring fitness- and other health-related metrics. The purpose of this systematic review was to summarize the evidence for validity and reliability of popular consumer-wearable activity trackers (Fitbit and Jawbone) and their ability to estimate steps, distance, physical activity, energy expenditure, and sleep. Methods Searches included only full-length English language studies published in PubMed, Embase, SPORTDiscus, and Google Scholar through July 31, 2015. Two people reviewed and abstracted each included study. Results In total, 22 studies were included in the review (20 on adults, 2 on youth). For laboratory-based studies using step counting or accelerometer steps, the correlation with tracker-assessed steps was high for both Fitbit and Jawbone (Pearson or intraclass correlation coefficients (CC) > =0.80). Only one study assessed distance for the Fitbit, finding an over-estimate at slower speeds and under-estimate at faster speeds. Two field-based studies compared accelerometry-assessed physical activity to the trackers, with one study finding higher correlation (Spearman CC 0.86, Fitbit) while another study found a wide range in correlation (intraclass CC 0.36–0.70, Fitbit and Jawbone). Using several different comparison measures (indirect and direct calorimetry, accelerometry, self-report), energy expenditure was more often under-estimated by either tracker. Total sleep time andAbstract Background Consumer-wearable activity trackers are electronic devices used for monitoring fitness- and other health-related metrics. The purpose of this systematic review was to summarize the evidence for validity and reliability of popular consumer-wearable activity trackers (Fitbit and Jawbone) and their ability to estimate steps, distance, physical activity, energy expenditure, and sleep. Methods Searches included only full-length English language studies published in PubMed, Embase, SPORTDiscus, and Google Scholar through July 31, 2015. Two people reviewed and abstracted each included study. Results In total, 22 studies were included in the review (20 on adults, 2 on youth). For laboratory-based studies using step counting or accelerometer steps, the correlation with tracker-assessed steps was high for both Fitbit and Jawbone (Pearson or intraclass correlation coefficients (CC) > =0.80). Only one study assessed distance for the Fitbit, finding an over-estimate at slower speeds and under-estimate at faster speeds. Two field-based studies compared accelerometry-assessed physical activity to the trackers, with one study finding higher correlation (Spearman CC 0.86, Fitbit) while another study found a wide range in correlation (intraclass CC 0.36–0.70, Fitbit and Jawbone). Using several different comparison measures (indirect and direct calorimetry, accelerometry, self-report), energy expenditure was more often under-estimated by either tracker. Total sleep time and sleep efficiency were over-estimated and wake after sleep onset was under-estimated comparing metrics from polysomnography to either tracker using a normal mode setting. No studies of intradevice reliability were found. Interdevice reliability was reported on seven studies using the Fitbit, but none for the Jawbone. Walking- and running-based Fitbit trials indicated consistently high interdevice reliability for steps (Pearson and intraclass CC 0.76–1.00), distance (intraclass CC 0.90–0.99), and energy expenditure (Pearson and intraclass CC 0.71–0.97). When wearing two Fitbits while sleeping, consistency between the devices was high. Conclusion This systematic review indicated higher validity of steps, few studies on distance and physical activity, and lower validity for energy expenditure and sleep. The evidence reviewed indicated high interdevice reliability for steps, distance, energy expenditure, and sleep for certain Fitbit models. As new activity trackers and features are introduced to the market, documentation of the measurement properties can guide their use in research settings. … (more)
- Is Part Of:
- International journal of behavioral nutrition and physical activity. Volume 12:Issue 1(2015)
- Journal:
- International journal of behavioral nutrition and physical activity
- Issue:
- Volume 12:Issue 1(2015)
- Issue Display:
- Volume 12, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 12
- Issue:
- 1
- Issue Sort Value:
- 2015-0012-0001-0000
- Page Start:
- 1
- Page End:
- 22
- Publication Date:
- 2015-12
- Subjects:
- Distance -- Energy expenditure -- Fitbit -- Intervention -- Jawbone -- Measurement -- Physical activity -- Sleep -- Steps -- Walking
Diet -- Periodicals
Physical fitness -- Periodicals
613.2 - Journal URLs:
- http://www.ijbnpa.org/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=243 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12966-015-0314-1 ↗
- Languages:
- English
- ISSNs:
- 1479-5868
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9998.xml