Fully automated treatment planning of spinal metastases – A comparison to manual planning of Volumetric Modulated Arc Therapy for conventionally fractionated irradiation. Issue 1 (December 2017)
- Record Type:
- Journal Article
- Title:
- Fully automated treatment planning of spinal metastases – A comparison to manual planning of Volumetric Modulated Arc Therapy for conventionally fractionated irradiation. Issue 1 (December 2017)
- Main Title:
- Fully automated treatment planning of spinal metastases – A comparison to manual planning of Volumetric Modulated Arc Therapy for conventionally fractionated irradiation
- Authors:
- Buergy, Daniel
Sharfo, Abdul
Heijmen, Ben
Voet, Peter
Breedveld, Sebastiaan
Wenz, Frederik
Lohr, Frank
Stieler, Florian - Abstract:
- Abstract Background Planning for Volumetric Modulated Arc Therapy (VMAT) may be time consuming and its use is limited by available staff resources. Automated multicriterial treatment planning can eliminate this bottleneck. We compared automatically created (auto) VMAT plans generated by Erasmus-iCycle to manually created VMAT plans for treatment of spinal metastases. Methods Forty-two targets in 32 patients were analyzed. Lungs and kidneys were defined as organs at risk (OARs). Twenty-two patients received radiotherapy on kidney levels, 17 on lung levels, and 3 on both levels. Results All Erasmus-iCycle plans were clinically acceptable. When compared to manual plans, planning target volume (PTV) coverage of auto plans was significantly better. The Homogeneity Index did not differ significantly between the groups. Mean dose to OARs was lower in auto plans concerning both kidneys and the left lung. One hotspot (>110% of D50% ) occurred in the spinal cord of one auto plan (33.2 Gy, D50% : 30 Gy). Treatment time was 7% longer in auto plans. Conclusions Erasmus-iCycle plans showed better target coverage and sparing of OARs at the expense of minimally longer treatment times (for which no constraint was set).
- Is Part Of:
- Radiation oncology. Volume 12:Issue 1(2017)
- Journal:
- Radiation oncology
- Issue:
- Volume 12:Issue 1(2017)
- Issue Display:
- Volume 12, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 12
- Issue:
- 1
- Issue Sort Value:
- 2017-0012-0001-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2017-12
- Subjects:
- Erasmus-iCycle -- Automated knowledge-based planning -- IMRT -- VMAT
Cancer -- Radiotherapy -- Periodicals
616.9940642 - Journal URLs:
- http://pubmedcentral.com/tocrender.fcgi?journal=402&action=archive ↗
http://www.ro-journal.com/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s13014-017-0767-2 ↗
- Languages:
- English
- ISSNs:
- 1748-717X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10008.xml