Electrospun electroactive nanofibers of gelatin‐oligoaniline/Poly (vinyl alcohol) templates for architecting of cardiac tissue with on‐demand drug release. (27th February 2019)
- Record Type:
- Journal Article
- Title:
- Electrospun electroactive nanofibers of gelatin‐oligoaniline/Poly (vinyl alcohol) templates for architecting of cardiac tissue with on‐demand drug release. (27th February 2019)
- Main Title:
- Electrospun electroactive nanofibers of gelatin‐oligoaniline/Poly (vinyl alcohol) templates for architecting of cardiac tissue with on‐demand drug release
- Authors:
- Shojaie, Shahrokh
Rostamian, Mostafa
Samadi, Ali
Alvani, Mohammad Amin Sabbagh
Khonakdar, Hossein Ali
Goodarzi, Vahabodin
Zarrintaj, Roya
Servatan, Morteza
Asefnejad, Azadeh
Baheiraei, Nafiseh
Saeb, Mohammad Reza - Abstract:
- Abstract : In this study, grafted gelatin with oligoaniline (GelOA) was synthesized and then mixed with Poly (vinyl alcohol) (PVA). Several scaffolds with different ratio of PVA/GelOA were electrospun to fabricate electroactive scaffolds. GelOA was characterized using Fourier‐transform infrared spectroscopy (FTIR); moreover, nanofiber properties were evaluated by differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and scanning electron microscope (SEM) analyses. Nanofibers diameter was decreased with aniline oligomer increment form 300 to 150 nm because of the hydrophobic nature of the aniline oligomer. Aniline oligomer electroactivity was studied using cyclic voltammetry, which exhibited two redox peaks at 0.4 and 0.6. Moreover, aniline oligomer enhancement resulted in melting point increasing from 220°C to 230°C because of the crystallinity increment. To assess the biocompatibility of nanofibers, cell viability and cell adhesion were tracked using mesenchymal stem cell (MSCs). It was revealed that the presence of aniline oligomer leads to enhancing the conductivity, thermal properties and lowering the degradation rate and drug release. Among of different scaffolds, sample with high content of GelOA shows better behavior in physical and biological properties. Accumulative drug releases under applied electrical field at 40 minutes showed that the drug release for stimulated condition is about 33% more than the unapplied electrical field one.
- Is Part Of:
- Polymers for advanced technologies. Volume 30:Number 6(2019)
- Journal:
- Polymers for advanced technologies
- Issue:
- Volume 30:Number 6(2019)
- Issue Display:
- Volume 30, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 6
- Issue Sort Value:
- 2019-0030-0006-0000
- Page Start:
- 1473
- Page End:
- 1483
- Publication Date:
- 2019-02-27
- Subjects:
- conductive fiber -- electroactive scaffold -- gelatin -- nanofiber -- oligoaniline -- tissue engineering
Polymers -- Periodicals
668.9 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/pat.4579 ↗
- Languages:
- English
- ISSNs:
- 1042-7147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6547.742200
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 10011.xml