Microscopic anisotropy misestimation in spherical‐mean single diffusion encoding MRI. Issue 5 (16th January 2019)
- Record Type:
- Journal Article
- Title:
- Microscopic anisotropy misestimation in spherical‐mean single diffusion encoding MRI. Issue 5 (16th January 2019)
- Main Title:
- Microscopic anisotropy misestimation in spherical‐mean single diffusion encoding MRI
- Authors:
- Henriques, Rafael Neto
Jespersen, Sune N.
Shemesh, Noam - Abstract:
- Abstract : Purpose: Microscopic fractional anisotropy (µFA) can disentangle microstructural information from orientation dispersion. While double diffusion encoding (DDE) MRI methods are widely used to extract accurate µFA, it has only recently been proposed that powder‐averaged single diffusion encoding (SDE) signals, when coupled with the diffusion standard model (SM) and a set of constraints, could be used for µFA estimation. This study aims to evaluate µFA as derived from the spherical mean technique (SMT) set of constraints, as well as more generally for powder‐averaged SM signals. Methods: SDE experiments were performed at 16.4 T on an ex vivo mouse brain (Δ/δ = 12/1.5 ms). The µFA maps obtained from powder‐averaged SDE signals were then compared to maps obtained from DDE‐MRI experiments (Δ/τ/δ = 12/12/1.5 ms), which allow a model‐free estimation of µFA. Theory and simulations that consider different types of heterogeneity are presented for corroborating the experimental findings. Results: µFA, as well as other estimates derived from powder‐averaged SDE signals produced large deviations from the ground truth in both gray and white matter. Simulations revealed that these misestimations are likely a consequence of factors not considered by the underlying microstructural models (such as intercomponent and intracompartmental kurtosis). Conclusion: Powder‐averaged SMT and (2‐component) SM are unable to accurately report µFA and other microstructural parameters in ex vivoAbstract : Purpose: Microscopic fractional anisotropy (µFA) can disentangle microstructural information from orientation dispersion. While double diffusion encoding (DDE) MRI methods are widely used to extract accurate µFA, it has only recently been proposed that powder‐averaged single diffusion encoding (SDE) signals, when coupled with the diffusion standard model (SM) and a set of constraints, could be used for µFA estimation. This study aims to evaluate µFA as derived from the spherical mean technique (SMT) set of constraints, as well as more generally for powder‐averaged SM signals. Methods: SDE experiments were performed at 16.4 T on an ex vivo mouse brain (Δ/δ = 12/1.5 ms). The µFA maps obtained from powder‐averaged SDE signals were then compared to maps obtained from DDE‐MRI experiments (Δ/τ/δ = 12/12/1.5 ms), which allow a model‐free estimation of µFA. Theory and simulations that consider different types of heterogeneity are presented for corroborating the experimental findings. Results: µFA, as well as other estimates derived from powder‐averaged SDE signals produced large deviations from the ground truth in both gray and white matter. Simulations revealed that these misestimations are likely a consequence of factors not considered by the underlying microstructural models (such as intercomponent and intracompartmental kurtosis). Conclusion: Powder‐averaged SMT and (2‐component) SM are unable to accurately report µFA and other microstructural parameters in ex vivo tissues. Improper model assumptions and constraints can significantly compromise parameter specificity. Further developments and validations are required prior to implementation of these models in clinical or preclinical research. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 5(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 5(2019)
- Issue Display:
- Volume 81, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 5
- Issue Sort Value:
- 2019-0081-0005-0000
- Page Start:
- 3245
- Page End:
- 3261
- Publication Date:
- 2019-01-16
- Subjects:
- double diffusion encoding -- diffusion kurtosis -- diffusion MRI -- diffusion tensor -- microscopic fractional anisotropy -- single diffusion encoding -- spherical mean technique
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27606 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10004.xml