Improved chemical exchange saturation transfer imaging with real‐time frequency drift correction. Issue 5 (30th January 2019)
- Record Type:
- Journal Article
- Title:
- Improved chemical exchange saturation transfer imaging with real‐time frequency drift correction. Issue 5 (30th January 2019)
- Main Title:
- Improved chemical exchange saturation transfer imaging with real‐time frequency drift correction
- Authors:
- Liu, Ruibin
Zhang, Hongxi
Niu, Weiming
Lai, Can
Ding, Qiuping
Chen, Weibo
Liang, Sayuan
Zhou, Jinyuan
Wu, Dan
Zhang, Yi - Abstract:
- Abstract : Purpose: To investigate the effects of frequency drift on chemical exchange saturation transfer (CEST) imaging at 3T, and to propose a new sequence for correcting artifacts attributed to B0 drift in real time. Theory and Methods: A frequency‐stabilized CEST (FS‐CEST) imaging sequence was proposed by adding a frequency stabilization module to the conventional non‐frequency‐stabilized CEST (NFS‐CEST) sequence, which consisted of a small tip angle radiofrequency excitation pulse and readout of three non‐phase‐encoded k ‐space lines. Experiments were performed on an egg white phantom and 26 human subjects on a heavy‐duty clinical scanner, in order to compare the difference of FS‐CEST and NFS‐CEST sequences for generating the z‐spectrum, magnetization transfer ratio asymmetry (MTRasym ) spectrum, and amide proton transfer weighted (APTw) image. Results: The B0 drift in CEST imaging, if not corrected, would cause APTw images and MTRasym spectra from both the phantom and volunteers to be either significantly higher or lower than the true values, depending on the status of the scanner. The FS‐CEST sequence generated substantially more stable MTRasym spectra and APTw images than the conventional NFS‐CEST sequence. Quantitatively, the compartmental‐average APTw signals (mean ± standard deviation) from frontal white matter regions of all 26 human subjects were –0.32% ± 2.32% for the NFS‐CEST sequence and –0.14% ± 0.37% for the FS‐CEST sequence. Conclusions: The proposedAbstract : Purpose: To investigate the effects of frequency drift on chemical exchange saturation transfer (CEST) imaging at 3T, and to propose a new sequence for correcting artifacts attributed to B0 drift in real time. Theory and Methods: A frequency‐stabilized CEST (FS‐CEST) imaging sequence was proposed by adding a frequency stabilization module to the conventional non‐frequency‐stabilized CEST (NFS‐CEST) sequence, which consisted of a small tip angle radiofrequency excitation pulse and readout of three non‐phase‐encoded k ‐space lines. Experiments were performed on an egg white phantom and 26 human subjects on a heavy‐duty clinical scanner, in order to compare the difference of FS‐CEST and NFS‐CEST sequences for generating the z‐spectrum, magnetization transfer ratio asymmetry (MTRasym ) spectrum, and amide proton transfer weighted (APTw) image. Results: The B0 drift in CEST imaging, if not corrected, would cause APTw images and MTRasym spectra from both the phantom and volunteers to be either significantly higher or lower than the true values, depending on the status of the scanner. The FS‐CEST sequence generated substantially more stable MTRasym spectra and APTw images than the conventional NFS‐CEST sequence. Quantitatively, the compartmental‐average APTw signals (mean ± standard deviation) from frontal white matter regions of all 26 human subjects were –0.32% ± 2.32% for the NFS‐CEST sequence and –0.14% ± 0.37% for the FS‐CEST sequence. Conclusions: The proposed FS‐CEST sequence provides an effective approach for B0 drift correction without additional scan time and should be adopted on heavy‐duty MRI scanners. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 5(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 5(2019)
- Issue Display:
- Volume 81, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 5
- Issue Sort Value:
- 2019-0081-0005-0000
- Page Start:
- 2915
- Page End:
- 2923
- Publication Date:
- 2019-01-30
- Subjects:
- amide proton transfer (APT) -- chemical exchange saturation transfer (CEST) -- frequency drift -- frequency stabilized CEST (FS‐CEST)
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27663 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10004.xml