Evaluation of the point-of-care Becton Dickinson Veritor™ Rapid influenza diagnostic test in Kenya, 2013–2014. Issue 1 (December 2017)
- Record Type:
- Journal Article
- Title:
- Evaluation of the point-of-care Becton Dickinson Veritor™ Rapid influenza diagnostic test in Kenya, 2013–2014. Issue 1 (December 2017)
- Main Title:
- Evaluation of the point-of-care Becton Dickinson Veritor™ Rapid influenza diagnostic test in Kenya, 2013–2014
- Authors:
- Ndegwa, Linus
Emukule, Gideon
Uyeki, Timothy
Mailu, Eunice
Chaves, Sandra
Widdowson, Marc-Alain
Lewa, Bandika
Muiruri, Francis
Omoth, Peter
Fields, Barry
Mott, Joshua - Abstract:
- Abstract Background We evaluated the performance of the Becton Dickinson Veritor™ System Flu A + B rapid influenza diagnostic test (RIDT) to detect influenza viruses in respiratory specimens from patients enrolled at five surveillance sites in Kenya, a tropical country where influenza seasonality is variable. Methods Nasal swab (NS) and nasopharyngeal (NP)/oropharyngeal (OP) swabs were collected from patients with influenza like illness and/or severe acute respiratory infection. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the RIDT using NS specimens were evaluated against nasal swabs tested by real time reverse transcription polymerase chain reaction (rRT-PCR). The performance parameter results were expressed as 95% confidence intervals (CI) calculated using binomial exact methods, withP < 0.05 considered significant. Two-sample Z tests were used to test for differences in sample proportions. Analysis was performed using SAS software version 9.3. Results From July 2013 to July 2014, 3, 569 patients were recruited, of which 78.7% were aged <5 years. Overall, 14.4% of NS specimens were influenza-positive by RIDT. RIDT overall sensitivity was 77.1% (95% CI 72.8–81.0%) and specificity was 94.9% (95% CI 94.0–95.7%) compared to rRT-PCR using NS specimens. RIDT sensitivity for influenza A virus compared to rRT-PCR using NS specimens was 71.8% (95% CI 66.7–76.4%) and was significantly higher than for influenza B which wasAbstract Background We evaluated the performance of the Becton Dickinson Veritor™ System Flu A + B rapid influenza diagnostic test (RIDT) to detect influenza viruses in respiratory specimens from patients enrolled at five surveillance sites in Kenya, a tropical country where influenza seasonality is variable. Methods Nasal swab (NS) and nasopharyngeal (NP)/oropharyngeal (OP) swabs were collected from patients with influenza like illness and/or severe acute respiratory infection. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the RIDT using NS specimens were evaluated against nasal swabs tested by real time reverse transcription polymerase chain reaction (rRT-PCR). The performance parameter results were expressed as 95% confidence intervals (CI) calculated using binomial exact methods, withP < 0.05 considered significant. Two-sample Z tests were used to test for differences in sample proportions. Analysis was performed using SAS software version 9.3. Results From July 2013 to July 2014, 3, 569 patients were recruited, of which 78.7% were aged <5 years. Overall, 14.4% of NS specimens were influenza-positive by RIDT. RIDT overall sensitivity was 77.1% (95% CI 72.8–81.0%) and specificity was 94.9% (95% CI 94.0–95.7%) compared to rRT-PCR using NS specimens. RIDT sensitivity for influenza A virus compared to rRT-PCR using NS specimens was 71.8% (95% CI 66.7–76.4%) and was significantly higher than for influenza B which was 43.8% (95% CI 33.8–54.2%). PPV ranged from 30%–80% depending on background prevalence of influenza. Conclusion Although the variable seasonality of influenza in tropical Africa presents unique challenges, RIDTs may have a role in making influenza surveillance sustainable in more remote areas of Africa, where laboratory capacity is limited. … (more)
- Is Part Of:
- BMC infectious diseases. Volume 17:Issue 1(2017)
- Journal:
- BMC infectious diseases
- Issue:
- Volume 17:Issue 1(2017)
- Issue Display:
- Volume 17, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2017-0017-0001-0000
- Page Start:
- 1
- Page End:
- 12
- Publication Date:
- 2017-12
- Subjects:
- Influenza -- Rapid influenza test -- Sensitivity and specificity -- Kenya
Communicable diseases -- Periodicals
Sexually Transmitted Diseases -- Periodicals
616.905 - Journal URLs:
- http://www.biomedcentral.com/bmcinfectdis/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=36 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12879-016-2131-9 ↗
- Languages:
- English
- ISSNs:
- 1471-2334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9983.xml