Evaluation of three-dimensional iterative image reconstruction in C-arm-based interventional cone-beam CT: A phantom study in comparison with customary reconstruction technique. Issue 13 (March 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation of three-dimensional iterative image reconstruction in C-arm-based interventional cone-beam CT: A phantom study in comparison with customary reconstruction technique. Issue 13 (March 2019)
- Main Title:
- Evaluation of three-dimensional iterative image reconstruction in C-arm-based interventional cone-beam CT
- Authors:
- Suzuki, Shigeru
Katada, Yoshiaki
Takayanagi, Tomoko
Sugawara, Haruto
Ishikawa, Takuya
Yamamoto, Yuzo
Wada, Hiroo - Other Names:
- Lucatelli. Pierleone section editor.
- Abstract:
- Abstract : Abstract: We compared images obtained using a three-dimensional iterative image reconstruction (3D-IIR) algorithm for C-arm-based interventional cone-beam computed tomography (CBCT) with that using the customary reconstruction technique to quantify the effect of reconstruction techniques on image quality. We scanned 2 phantoms using an angiography unit with digital flat-panel system—an elliptical cylinder acrylic phantom to evaluate spatial resolution and a Catphan phantom to evaluate CT number linearity, image noise, and low-contrast resolution. Three-dimensional imaging was calculated using Feldkamp algorithms, and additional image sets were reconstructed using 3D-IIR at 5 settings (Sharp, Default, Soft+, Soft++, Soft+++). We evaluated quality of images obtained using the 6 reconstruction techniques and analyzed variance to test values of the 10% value of each MTF, mean CT number, and contrast-to-noise ratio (CNR), with P < .05 considered statistically significant. Modulation transfer function curves and CT number linearity among images obtained using the customary technique and the 5 3D-IIR techniques showed excellent agreement. Noise power spectrum curves demonstrated uniform noise reduction across the spatial frequency in the iterative reconstruction, and CNR obtained using all but the Sharp 3D-IIR technique was significantly better than that using the customary reconstruction technique (Sharp, P = .1957; Default, P = .0042; others, P < .0001). Use ofAbstract : Abstract: We compared images obtained using a three-dimensional iterative image reconstruction (3D-IIR) algorithm for C-arm-based interventional cone-beam computed tomography (CBCT) with that using the customary reconstruction technique to quantify the effect of reconstruction techniques on image quality. We scanned 2 phantoms using an angiography unit with digital flat-panel system—an elliptical cylinder acrylic phantom to evaluate spatial resolution and a Catphan phantom to evaluate CT number linearity, image noise, and low-contrast resolution. Three-dimensional imaging was calculated using Feldkamp algorithms, and additional image sets were reconstructed using 3D-IIR at 5 settings (Sharp, Default, Soft+, Soft++, Soft+++). We evaluated quality of images obtained using the 6 reconstruction techniques and analyzed variance to test values of the 10% value of each MTF, mean CT number, and contrast-to-noise ratio (CNR), with P < .05 considered statistically significant. Modulation transfer function curves and CT number linearity among images obtained using the customary technique and the 5 3D-IIR techniques showed excellent agreement. Noise power spectrum curves demonstrated uniform noise reduction across the spatial frequency in the iterative reconstruction, and CNR obtained using all but the Sharp 3D-IIR technique was significantly better than that using the customary reconstruction technique (Sharp, P = .1957; Default, P = .0042; others, P < .0001). Use of 3D-IIR, especially the Soft++ and Soft+++ settings, improved visualization of low-contrast targets. Use of a 3D-IIR can significantly improve image noise and low-contrast resolution while maintaining spatial resolution in C-arm-based interventional CBCT, yielding higher quality images that may increase safety and efficacy in interventional radiology. … (more)
- Is Part Of:
- Medicine. Volume 98:Issue 13(2019)
- Journal:
- Medicine
- Issue:
- Volume 98:Issue 13(2019)
- Issue Display:
- Volume 98, Issue 13 (2019)
- Year:
- 2019
- Volume:
- 98
- Issue:
- 13
- Issue Sort Value:
- 2019-0098-0013-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-03
- Subjects:
- angiography -- experimental studies -- image reconstruction -- image-based iterative reconstruction
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000014947 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9977.xml