Three-Dimensional Printed Biopatches With Conductive Ink Facilitate Cardiac Conduction When Applied to Disrupted Myocardium. (March 2019)
- Record Type:
- Journal Article
- Title:
- Three-Dimensional Printed Biopatches With Conductive Ink Facilitate Cardiac Conduction When Applied to Disrupted Myocardium. (March 2019)
- Main Title:
- Three-Dimensional Printed Biopatches With Conductive Ink Facilitate Cardiac Conduction When Applied to Disrupted Myocardium
- Authors:
- Pedrotty, Dawn M.
Kuzmenko, Volodymyr
Karabulut, Erdem
Sugrue, Alan M.
Livia, Christopher
Vaidya, Vaibhav R.
McLeod, Christopher J.
Asirvatham, Samuel J.
Gatenholm, Paul
Kapa, Suraj - Abstract:
- Abstract : Background: Reentrant ventricular arrhythmias are a major cause of sudden death in patients with structural heart disease. Current treatments focus on electrically homogenizing regions of scar contributing to ventricular arrhythmia with ablation or altering conductive properties using antiarrhythmic drugs. The high conductivity of carbon nanotubes may allow restoration of conduction in regions where impaired electrical conduction results in functional abnormalities. We propose a new concept for arrhythmia treatment using a stretchable, flexible biopatch with conductive properties to attempt to restore conduction across regions in which activation is disrupted. Methods: Carbon nanotube patches composed of nanofibrillated cellulose/single-walled carbon nanotube ink 3-dimensionally printed in conductive patterns onto bacterial nanocellulose were developed and evaluated for conductivity, flexibility, and mechanical properties. The patches were applied on 6 canines to epicardium before and after surgical disruption. Electroanatomic mapping was performed on normal epicardium, then repeated over surgically disrupted epicardium, and then finally with the patch applied passively. Results: We developed a 3-dimensional printable carbon nanotube ink complexed on bacterial nanocellulose that was (1) expressable through 3-dimensional printer nozzles, (2) electrically conductive, (3) flexible, and (4) stretchable. Six canines underwent thoracotomy, and, during epicardialAbstract : Background: Reentrant ventricular arrhythmias are a major cause of sudden death in patients with structural heart disease. Current treatments focus on electrically homogenizing regions of scar contributing to ventricular arrhythmia with ablation or altering conductive properties using antiarrhythmic drugs. The high conductivity of carbon nanotubes may allow restoration of conduction in regions where impaired electrical conduction results in functional abnormalities. We propose a new concept for arrhythmia treatment using a stretchable, flexible biopatch with conductive properties to attempt to restore conduction across regions in which activation is disrupted. Methods: Carbon nanotube patches composed of nanofibrillated cellulose/single-walled carbon nanotube ink 3-dimensionally printed in conductive patterns onto bacterial nanocellulose were developed and evaluated for conductivity, flexibility, and mechanical properties. The patches were applied on 6 canines to epicardium before and after surgical disruption. Electroanatomic mapping was performed on normal epicardium, then repeated over surgically disrupted epicardium, and then finally with the patch applied passively. Results: We developed a 3-dimensional printable carbon nanotube ink complexed on bacterial nanocellulose that was (1) expressable through 3-dimensional printer nozzles, (2) electrically conductive, (3) flexible, and (4) stretchable. Six canines underwent thoracotomy, and, during epicardial ventricular pacing, mapping was performed. We demonstrated disruption of conduction after surgical incision in all 6 canines based on activation mapping. The patch resulted in restored conduction based on mapping and assessment of conduction direction and velocities in all canines. Conclusions: We have demonstrated 3-dimensional custom-printed electrically conductive carbon nanotube patches can be surgically manipulated to improve cardiac conduction when passively applied to surgically disrupted epicardial myocardium in canines. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 12:Number 3(2019)
- Journal:
- Circulation
- Issue:
- Volume 12:Number 3(2019)
- Issue Display:
- Volume 12, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 12
- Issue:
- 3
- Issue Sort Value:
- 2019-0012-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-03
- Subjects:
- electrophysiology -- ink -- mapping -- nanotubes, carbon
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.118.006920 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9981.xml