Discriminant validity and test re-test reproducibility of a gait assessment in patients with vestibular dysfunction. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Discriminant validity and test re-test reproducibility of a gait assessment in patients with vestibular dysfunction. Issue 1 (December 2015)
- Main Title:
- Discriminant validity and test re-test reproducibility of a gait assessment in patients with vestibular dysfunction
- Authors:
- Schmidheiny, Annatina
Swanenburg, Jaap
Straumann, Dominik
de Bruin, Eling
Knols, Ruud - Abstract:
- Abstract Background Gait function may be impaired in patients with vestibular disorders, making gait assessment in the clinical setting relevant for this patient population. The purpose of this study was to evaluate the discriminant validity of a gait assessment protocol between patients with vestibular disorders and healthy participants. Furthermore, test re-test reproducibility and the measurement error of gait performance measures in patients with vestibular lesions was performed under different walking conditions. Methods Gait parameters of thirty-five patients with vestibular disorders and twenty-seven healthy controls were assessed twice with the GAITRite® system. Discriminant validity, reproducibility (intra class correlation [ICC]) and the measurement error (standard error of measurement [SEM], smallest detectable change [SDC]) were determined for gait speed, cadence and step length. Bland-Altman plots were made to assess systematic bias between tests. Results A significant effect of grouping on gait performance indicates discriminant validity of gait assessment. All tests revealed differences between patients and healthy controls (p < 0.01). The ICCs for test re-test reproducibility were excellent (0.70-0.96) and measurement error showed acceptable SDC values for gait parameters derived from three walking conditions (9-19 %). Bland-Altman plots indicated no systematic bias. Conclusions Good validity and reproducibility of GAITRite® system measurements suggest thatAbstract Background Gait function may be impaired in patients with vestibular disorders, making gait assessment in the clinical setting relevant for this patient population. The purpose of this study was to evaluate the discriminant validity of a gait assessment protocol between patients with vestibular disorders and healthy participants. Furthermore, test re-test reproducibility and the measurement error of gait performance measures in patients with vestibular lesions was performed under different walking conditions. Methods Gait parameters of thirty-five patients with vestibular disorders and twenty-seven healthy controls were assessed twice with the GAITRite® system. Discriminant validity, reproducibility (intra class correlation [ICC]) and the measurement error (standard error of measurement [SEM], smallest detectable change [SDC]) were determined for gait speed, cadence and step length. Bland-Altman plots were made to assess systematic bias between tests. Results A significant effect of grouping on gait performance indicates discriminant validity of gait assessment. All tests revealed differences between patients and healthy controls (p < 0.01). The ICCs for test re-test reproducibility were excellent (0.70-0.96) and measurement error showed acceptable SDC values for gait parameters derived from three walking conditions (9-19 %). Bland-Altman plots indicated no systematic bias. Conclusions Good validity and reproducibility of GAITRite® system measurements suggest that this system could facilitate the study of gait in patients with vestibular disorders in clinical settings. The SDC values for gait are generally small enough to detect changes after a rehabilitation program for patients with vestibular disorders. … (more)
- Is Part Of:
- BMC ear, nose, and throat disorders. Volume 15:Issue 1(2015)
- Journal:
- BMC ear, nose, and throat disorders
- Issue:
- Volume 15:Issue 1(2015)
- Issue Display:
- Volume 15, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2015-0015-0001-0000
- Page Start:
- 1
- Page End:
- 10
- Publication Date:
- 2015-12
- Subjects:
- Vestibular diseases -- Gait analysis -- Validity -- Reliability
Otolaryngology -- Periodicals
617.51005 - Journal URLs:
- http://www.biomedcentral.com/1472-6815 ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=24 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12901-015-0019-8 ↗
- Languages:
- English
- ISSNs:
- 1472-6815
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9993.xml