- Reticular telangiectatic erythema from implanted devices attributed to low‐grade infection with Staphylococcus epidermidis
- Authors:
- Wuyts, Laura
Van Dyck, Frederic
Kamerling, Niels
Olyslaegers, Christophe
Jansens, Hilde
Lambert, Julien
Aerts, Olivier - Abstract:
- Abstract: Reticular telangiectatic erythema (RTE) is a poorly defined clinical condition occurring days, months to even years after the implantation of medical devices such as orthopaedic prostheses, neurostimulators and pacemakers. In its pathogenesis a role for Staphylococcus epidermidis has been suggested, but such cases have only rarely been reported. We describe three patients, one with a neurostimulator and two with an orthopaedic prosthesis, respectively, in whom a RTE developed and, ultimately, could be attributed to a low‐grade infection with the biofilm‐producing S. epidermidis . The devices showed no apparent technical defects and patch tests, to exclude a contact‐allergic origin of the RTE, were negative in all cases. However, an antimicrobial strategy, including antibiotic therapy and removal of the infected devices, led to complete disappearance of the RTE in all cases. The subsequent and uneventful replacement by a new, but identical, medical device, in two of three patients, further argues for a potential aetiologic role of S. epidermidis in the occurrence of some cases of—otherwise unexplained—RTE.
- Is Part Of:
- Medical devices & sensors. Volume 2:Issue 1(2019)
- Journal:
- Medical devices & sensors
- Issue:
- Volume 2:Issue 1(2019)
- Issue Display:
- Volume 2, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 2
- Issue:
- 1
- Issue Sort Value:
- 2019-0002-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-02-15
- Subjects:
- biofilm -- implants -- low‐grade infection -- post‐implantation erythema -- reticular telangiectatic erythema -- Staphylococcus epidermidis
Medical instruments and apparatus -- Periodicals
Biomedical engineering -- Periodicals
Electronic journals
Periodicals
610.28 - Journal URLs:
- https://onlinelibrary.wiley.com/journal/2573802x ↗
- DOI:
- 10.1002/mds3.10023 ↗
- Languages:
- English
- ISSNs:
- 2573-802X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.055436
British Library HMNTS - ELD Digital store - Ingest File:
- 9989.xml