Evaluation and validation of an analytical approach for high-throughput metabolomic fingerprinting using direct introduction–high-resolution mass spectrometry: Applicability to classification of urine of scrapie-infected ewes. Issue 2 (April 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation and validation of an analytical approach for high-throughput metabolomic fingerprinting using direct introduction–high-resolution mass spectrometry: Applicability to classification of urine of scrapie-infected ewes. Issue 2 (April 2019)
- Main Title:
- Evaluation and validation of an analytical approach for high-throughput metabolomic fingerprinting using direct introduction–high-resolution mass spectrometry: Applicability to classification of urine of scrapie-infected ewes
- Authors:
- Rathahao-Paris, Estelle
Alves, Sandra
Boussaid, Nawel
Picard-Hagen, Nicole
Gayrard, Véronique
Toutain, Pierre-Louis
Tabet, Jean-Claude
Rutledge, Douglas N
Paris, Alain - Abstract:
- Direct injection–mass spectrometry can be used to perform high-throughput metabolomic fingerprinting. This work aims to evaluate a global analytical workflow in terms of sample preparation (urine sample dilution), high-resolution detection (quality of generated data based on criteria such as mass measurement accuracy and detection sensitivity) and data analysis using dedicated bioinformatics tools. Investigation was performed on a large number of biological samples collected from sheep infected or not with scrapie. Direct injection–mass spectrometry approach is usually affected by matrix effects, eventually hampering detection of some relevant biomarkers. Reference compounds were spiked in biological samples to help evaluate the quality of direct injection–mass spectrometry data produced by Fourier Transform mass spectrometry. Despite the potential of high-resolution detection, some drawbacks still remain. The most critical is the presence of matrix effects, which could be minimized by optimizing the sample dilution factor. The data quality in terms of mass measurement accuracy and reproducible intensity was evaluated. Good repeatability was obtained for the chosen dilution factor (i.e., 2000). More than 150 analyses were performed in less than 16 hours using the optimized direct injection–mass spectrometry approach. Discrimination of different status of sheeps in relation to scrapie infection (i.e., scrapie-affected, preclinical scrapie or healthy) was obtained from theDirect injection–mass spectrometry can be used to perform high-throughput metabolomic fingerprinting. This work aims to evaluate a global analytical workflow in terms of sample preparation (urine sample dilution), high-resolution detection (quality of generated data based on criteria such as mass measurement accuracy and detection sensitivity) and data analysis using dedicated bioinformatics tools. Investigation was performed on a large number of biological samples collected from sheep infected or not with scrapie. Direct injection–mass spectrometry approach is usually affected by matrix effects, eventually hampering detection of some relevant biomarkers. Reference compounds were spiked in biological samples to help evaluate the quality of direct injection–mass spectrometry data produced by Fourier Transform mass spectrometry. Despite the potential of high-resolution detection, some drawbacks still remain. The most critical is the presence of matrix effects, which could be minimized by optimizing the sample dilution factor. The data quality in terms of mass measurement accuracy and reproducible intensity was evaluated. Good repeatability was obtained for the chosen dilution factor (i.e., 2000). More than 150 analyses were performed in less than 16 hours using the optimized direct injection–mass spectrometry approach. Discrimination of different status of sheeps in relation to scrapie infection (i.e., scrapie-affected, preclinical scrapie or healthy) was obtained from the application of Shrinkage Discriminant Analysis to the direct injection–mass spectrometry data. The most relevant variables related to this discrimination were selected and annotated. This study demonstrated that the choice of appropriated dilution faction is indispensable for producing quality and informative direct injection–mass spectrometry data. Successful application of direct injection–mass spectrometry approach for high throughput analysis of a large number of biological samples constitutes the proof of the concept. … (more)
- Is Part Of:
- European journal of mass spectrometry. Volume 25:Issue 2(2019)
- Journal:
- European journal of mass spectrometry
- Issue:
- Volume 25:Issue 2(2019)
- Issue Display:
- Volume 25, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 25
- Issue:
- 2
- Issue Sort Value:
- 2019-0025-0002-0000
- Page Start:
- 251
- Page End:
- 258
- Publication Date:
- 2019-04
- Subjects:
- High-throughput metabolomics -- direct injection–mass spectrometry -- high-resolution mass spectrometry -- matrix effects -- data analysis
Mass spectrometry -- Periodicals
Mass Spectrometry
Mass spectrometry
Periodicals
Periodicals
543.6505 - Journal URLs:
- http://www.impub.co.uk/ems.html ↗
http://journals.sagepub.com/toc/EMS/current ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1469066718806450 ↗
- Languages:
- English
- ISSNs:
- 1469-0667
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9966.xml