Which factors should be considered in choosing pessary type and size for pelvic organ prolapse patients in a fitting trial?. Issue 12 (December 2016)
- Record Type:
- Journal Article
- Title:
- Which factors should be considered in choosing pessary type and size for pelvic organ prolapse patients in a fitting trial?. Issue 12 (December 2016)
- Main Title:
- Which factors should be considered in choosing pessary type and size for pelvic organ prolapse patients in a fitting trial?
- Authors:
- Ding, Jing
Song, Xiao-chen
Deng, Mou
Zhu, Lan - Abstract:
- Abstract Introduction and hypothesis This study explored whether the optimal pessary type and size can be predicted using the specific pelvic organ prolapse quantification system (POP-Q) measurements in women with pelvic organ prolapse in a fitting trial. Methods We conducted a prospective study in women who had undergone pessary fitting. A total of 78 patients with stage II, III or IV symptomatic pelvic organ prolapse completed a detailed history. Data were analysed using nonparametric tests, continuity correction chi-squared tests and multivariate logistic regression. Results Differences in total vaginal length (TVL;p < 0.01) and vaginal introitus width/TVL ratio (p = 0.012) were observed between patients with and without a history of hysterectomy. Patients with a history of hysterectomy and patients with a larger vaginal introitus had more success with the Gellhorn pessary than with the ring pessary with support (p = 0.005 andp = 0.01, respectively). Factors determining the size of the ring pessary with support were the genital hiatus (GH) width (p = 0.044), TVL (p = 0.011), vaginal introitus width (p < 0.001), and vaginal introitus width/TVL ratio (p = 0.025). Factors determining the size of the Gellhorn pessary were the GH width (p = 0.025), GH width/TVL ratio (p = 0.013), vaginal introitus width (p = 0.003), vaginal introitus width/TVL ratio (p = 0.001), stage of apical prolapse (p = 0.006) and stage of posterior prolapse (p = 0.003). Conclusions PatientsAbstract Introduction and hypothesis This study explored whether the optimal pessary type and size can be predicted using the specific pelvic organ prolapse quantification system (POP-Q) measurements in women with pelvic organ prolapse in a fitting trial. Methods We conducted a prospective study in women who had undergone pessary fitting. A total of 78 patients with stage II, III or IV symptomatic pelvic organ prolapse completed a detailed history. Data were analysed using nonparametric tests, continuity correction chi-squared tests and multivariate logistic regression. Results Differences in total vaginal length (TVL;p < 0.01) and vaginal introitus width/TVL ratio (p = 0.012) were observed between patients with and without a history of hysterectomy. Patients with a history of hysterectomy and patients with a larger vaginal introitus had more success with the Gellhorn pessary than with the ring pessary with support (p = 0.005 andp = 0.01, respectively). Factors determining the size of the ring pessary with support were the genital hiatus (GH) width (p = 0.044), TVL (p = 0.011), vaginal introitus width (p < 0.001), and vaginal introitus width/TVL ratio (p = 0.025). Factors determining the size of the Gellhorn pessary were the GH width (p = 0.025), GH width/TVL ratio (p = 0.013), vaginal introitus width (p = 0.003), vaginal introitus width/TVL ratio (p = 0.001), stage of apical prolapse (p = 0.006) and stage of posterior prolapse (p = 0.003). Conclusions Patients with a history of hysterectomy or with a larger vaginal introitus were more likely to achieve success with the Gellhorn pessary. The GH width and the vaginal introitus width influenced the size of both pessaries chosen. The TVL was predictive of the optimal size of the ring pessary with support but was not predictive of the optimal size of the Gellhorn pessary. Finally, the size of the Gellhorn pessary was associated with POP stage. … (more)
- Is Part Of:
- International urogynecology journal. Volume 27:Issue 12(2016)
- Journal:
- International urogynecology journal
- Issue:
- Volume 27:Issue 12(2016)
- Issue Display:
- Volume 27, Issue 12 (2016)
- Year:
- 2016
- Volume:
- 27
- Issue:
- 12
- Issue Sort Value:
- 2016-0027-0012-0000
- Page Start:
- 1867
- Page End:
- 1871
- Publication Date:
- 2016-12
- Subjects:
- Pelvic organ prolapse -- Pessary -- Type and size -- Fitting trial -- POP-Q -- Vaginal introitus
Urogynecology -- Periodicals
Generative organs, Female -- Diseases -- Periodicals
616.60082 - Journal URLs:
- http://springerlink.metapress.com/openurl.asp?genre=journal&eissn=1433-3023 ↗
http://www.springerlink.com/content/102824 ↗
http://www.springerlink.com/openurl.asp?genre=journal&issn=0937-3462 ↗
http://www.springer.com/gb/ ↗
http://www.springer.com/gb/ ↗ - DOI:
- 10.1007/s00192-016-3051-3 ↗
- Languages:
- English
- ISSNs:
- 0937-3462
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4551.567800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9975.xml