Lung hyperaeration assessment by computed tomography: correction of reconstruction-induced bias. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Lung hyperaeration assessment by computed tomography: correction of reconstruction-induced bias. Issue 1 (December 2015)
- Main Title:
- Lung hyperaeration assessment by computed tomography: correction of reconstruction-induced bias
- Authors:
- Ball, Lorenzo
Brusasco, Claudia
Corradi, Francesco
Paparo, Francesco
Garlaschi, Alessandro
Herrmann, Peter
Quintel, Michael
Pelosi, Paolo - Abstract:
- Abstract Background Computed tomography (CT) reconstruction parameters, such as slice thickness and convolution kernel, significantly affect the quantification of hyperaerated parenchyma (VHYPER %). The aim of this study was to investigate the mathematical relation between VHYPER % calculated at different reconstruction settings, in mechanically ventilated and spontaneously breathing patients with different lung pathology. Methods In this retrospective observational study, CT scans of patients of the intensive care unit and emergency department were collected from two CT scanners and analysed with different kernel-thickness combinations (reconstructions): 1.25 mm soft kernel, 5 mm soft kernel, 5 mm sharp kernel in the first scanner; 2.5 mm slice thickness with a smooth (B41s) and a sharp (B70s) kernel on the second scanner. A quantitative analysis was performed with Maluna® to assess lung aeration compartments as percent of total lung volume. CT variables calculated with different reconstructions were compared in pairs, and their mathematical relationship was analysed by using quadratic and power functions. Results 43 subjects were included in the present analysis. Image reconstruction parameters influenced all the quantitative CT-derived variables. The most relevant changes occurred in the hyperaerated and normally aerated volume compartments. The application of a power correction formula led to a significant reduction in the bias between VHYPER % estimations (p < 0.001 inAbstract Background Computed tomography (CT) reconstruction parameters, such as slice thickness and convolution kernel, significantly affect the quantification of hyperaerated parenchyma (VHYPER %). The aim of this study was to investigate the mathematical relation between VHYPER % calculated at different reconstruction settings, in mechanically ventilated and spontaneously breathing patients with different lung pathology. Methods In this retrospective observational study, CT scans of patients of the intensive care unit and emergency department were collected from two CT scanners and analysed with different kernel-thickness combinations (reconstructions): 1.25 mm soft kernel, 5 mm soft kernel, 5 mm sharp kernel in the first scanner; 2.5 mm slice thickness with a smooth (B41s) and a sharp (B70s) kernel on the second scanner. A quantitative analysis was performed with Maluna® to assess lung aeration compartments as percent of total lung volume. CT variables calculated with different reconstructions were compared in pairs, and their mathematical relationship was analysed by using quadratic and power functions. Results 43 subjects were included in the present analysis. Image reconstruction parameters influenced all the quantitative CT-derived variables. The most relevant changes occurred in the hyperaerated and normally aerated volume compartments. The application of a power correction formula led to a significant reduction in the bias between VHYPER % estimations (p < 0.001 in all cases). The bias in VHYPER % assessment did not differ between lung pathology nor ventilation mode groups (p > 0.15 in all cases). Conclusions Hyperaerated percent volume at different reconstruction settings can be described by a fixed mathematical relationship, independent of lung pathology, ventilation mode, and type of CT scanner. … (more)
- Is Part Of:
- BMC anesthesiology. Volume 16:Issue 1(2016)
- Journal:
- BMC anesthesiology
- Issue:
- Volume 16:Issue 1(2016)
- Issue Display:
- Volume 16, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 16
- Issue:
- 1
- Issue Sort Value:
- 2016-0016-0001-0000
- Page Start:
- 1
- Page End:
- 7
- Publication Date:
- 2015-12
- Subjects:
- Anesthetics -- Periodicals
Anesthesia -- Periodicals
Anesthesiology -- Periodicals
617.9605 - Journal URLs:
- http://www.biomedcentral.com/bmcanesthesiol/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=11 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12871-016-0232-z ↗
- Languages:
- English
- ISSNs:
- 1471-2253
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 9973.xml