Effect of timing of hip extension assistance during loaded walking with a soft exosuit. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- Effect of timing of hip extension assistance during loaded walking with a soft exosuit. Issue 1 (December 2016)
- Main Title:
- Effect of timing of hip extension assistance during loaded walking with a soft exosuit
- Authors:
- Ding, Ye
Panizzolo, Fausto
Siviy, Christopher
Malcolm, Philippe
Galiana, Ignacio
Holt, Kenneth
Walsh, Conor - Abstract:
- Abstract Background Recent advances in wearable robotic devices have demonstrated the ability to reduce the metabolic cost of walking by assisting the ankle joint. To achieve greater gains in the future it will be important to determine optimal actuation parameters and explore the effect of assisting other joints. The aim of the present work is to investigate how the timing of hip extension assistance affects the positive mechanical power delivered by an exosuit and its effect on biological joint power and metabolic cost during loaded walking. In this study, we evaluated 4 different hip assistive profiles with different actuation timings: early-start-early-peak (ESEP), early-start-late-peak (ESLP), late-start-early-peak (LSEP), late-start-late-peak (LSLP). Methods Eight healthy participants walked on a treadmill at a constant speed of 1.5 m · s-1 while carrying a 23 kg backpack load. We tested five different conditions: four with the assistive profiles described above and one unpowered condition where no assistance was provided. We evaluated participants' lower limb kinetics, kinematics, metabolic cost and muscle activation. Results The variation of timing in the hip extension assistance resulted in a different amount of mechanical power delivered to the wearer across conditions; with the ESLP condition providing a significantly higher amount of positive mechanical power (0.219 ± 0.006 W · kg-1 ) with respect to the other powered conditions. Biological joint power wasAbstract Background Recent advances in wearable robotic devices have demonstrated the ability to reduce the metabolic cost of walking by assisting the ankle joint. To achieve greater gains in the future it will be important to determine optimal actuation parameters and explore the effect of assisting other joints. The aim of the present work is to investigate how the timing of hip extension assistance affects the positive mechanical power delivered by an exosuit and its effect on biological joint power and metabolic cost during loaded walking. In this study, we evaluated 4 different hip assistive profiles with different actuation timings: early-start-early-peak (ESEP), early-start-late-peak (ESLP), late-start-early-peak (LSEP), late-start-late-peak (LSLP). Methods Eight healthy participants walked on a treadmill at a constant speed of 1.5 m · s-1 while carrying a 23 kg backpack load. We tested five different conditions: four with the assistive profiles described above and one unpowered condition where no assistance was provided. We evaluated participants' lower limb kinetics, kinematics, metabolic cost and muscle activation. Results The variation of timing in the hip extension assistance resulted in a different amount of mechanical power delivered to the wearer across conditions; with the ESLP condition providing a significantly higher amount of positive mechanical power (0.219 ± 0.006 W · kg-1 ) with respect to the other powered conditions. Biological joint power was significantly reduced at the hip (ESEP and ESLP) and at the knee (ESEP, ESLP and LSEP) with respect to the unpowered condition. Further, all assistive profiles significantly reduced the metabolic cost of walking compared to the unpowered condition by 5.7 ± 1.5 %, 8.5 ± 0.9 %, 6.3 ± 1.4 % and 7.1 ± 1.9 % (mean ± SE for ESEP, ESLP, LSEP, LSLP, respectively). Conclusions The highest positive mechanical power delivered by the soft exosuit was reported in the ESLP condition, which showed also a significant reduction in both biological hip and knee joint power. Further, the ESLP condition had the highest average metabolic reduction among the powered conditions. Future work on autonomous hip exoskeletons may incorporate these considerations when designing effective control strategies. … (more)
- Is Part Of:
- Journal of neuroengineering and rehabilitation. Volume 13:Issue 1(2016)
- Journal:
- Journal of neuroengineering and rehabilitation
- Issue:
- Volume 13:Issue 1(2016)
- Issue Display:
- Volume 13, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 13
- Issue:
- 1
- Issue Sort Value:
- 2016-0013-0001-0000
- Page Start:
- 1
- Page End:
- 10
- Publication Date:
- 2016-12
- Subjects:
- Nervous system -- Diseases -- Patients -- Rehabilitation -- Periodicals
Nervous system -- Wounds and injuries -- Rehabilitation -- Periodicals
Biomedical engineering
616.8043005 - Journal URLs:
- http://www.jneuroengrehab.com/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12984-016-0196-8 ↗
- Languages:
- English
- ISSNs:
- 1743-0003
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: