Diagnostic accuracy of methacholine challenge tests assessing airway hyperreactivity in asthmatic patients - a multifunctional approach. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of methacholine challenge tests assessing airway hyperreactivity in asthmatic patients - a multifunctional approach. Issue 1 (December 2016)
- Main Title:
- Diagnostic accuracy of methacholine challenge tests assessing airway hyperreactivity in asthmatic patients - a multifunctional approach
- Authors:
- Kraemer, Richard
Smith, Hans-Jürgen
Sigrist, Thomas
Giger, Gabi
Keller, Roland
Frey, Martin - Abstract:
- Abstract Background There are few studies comparing diagnostic accuracy of different lung function parameters evaluating dose–response characteristics of methacholine (MCH) challenge tests (MCT) as quantitative outcome of airway hyperreactivity (AHR) in asthmatic patients. The aim of this retrospectively analysis of our database (Clinic Barmelweid, Switzerland) was, to assess diagnostic accuracy of several lung function parameters quantitating AHR by dose–response characteristics. Methods Changes in effective specific airway conductance (sGeff ) as estimate of the degree of bronchial obstruction were compared with concomitantly measured forced expiratory volume in 1 s (FEV1 ) and forced expiratory flows at 50% forced vital capacity (FEF50 ). According to the GINA Guidelines the patients (n = 484) were classified into asthmatic patients (n = 337) and non-asthmatic subjects (n = 147). Whole-body plethysmography (CareFusion, Würzburg, Germany) was performed using ATS-ERS criteria, and for the MCTs a standardised computer controlled protocol with 3 consecutive cumulative provocation doses (PD1 : 0.2 mg; PD2 : 1.0 mg; PD3 : 2.2 mg) was used. Break off criterion for the MCTs were when a decrease in FEV1 of 20% was reached or respiratory symptoms occurred. Results In the assessment of AHR, whole-body plethysmography offers in addition to spirometry indices of airways conductance and thoracic lung volumes, which are incorporated in the parameter sGeff, derived from spontaneousAbstract Background There are few studies comparing diagnostic accuracy of different lung function parameters evaluating dose–response characteristics of methacholine (MCH) challenge tests (MCT) as quantitative outcome of airway hyperreactivity (AHR) in asthmatic patients. The aim of this retrospectively analysis of our database (Clinic Barmelweid, Switzerland) was, to assess diagnostic accuracy of several lung function parameters quantitating AHR by dose–response characteristics. Methods Changes in effective specific airway conductance (sGeff ) as estimate of the degree of bronchial obstruction were compared with concomitantly measured forced expiratory volume in 1 s (FEV1 ) and forced expiratory flows at 50% forced vital capacity (FEF50 ). According to the GINA Guidelines the patients (n = 484) were classified into asthmatic patients (n = 337) and non-asthmatic subjects (n = 147). Whole-body plethysmography (CareFusion, Würzburg, Germany) was performed using ATS-ERS criteria, and for the MCTs a standardised computer controlled protocol with 3 consecutive cumulative provocation doses (PD1 : 0.2 mg; PD2 : 1.0 mg; PD3 : 2.2 mg) was used. Break off criterion for the MCTs were when a decrease in FEV1 of 20% was reached or respiratory symptoms occurred. Results In the assessment of AHR, whole-body plethysmography offers in addition to spirometry indices of airways conductance and thoracic lung volumes, which are incorporated in the parameter sGeff, derived from spontaneous tidal breathing. The cumulative percent dose-responses at each provocation step were at the 1st level step (0.2 mg MCH) 3.7 times, at the 2nd level step (1 mg MCH) 2.4 times, and at the 3rd level step (2.2 mg MCH) 2.0 times more pronounced for sGeff, compared to FEV1 . A much better diagnostic odds ratio of sGeff (7.855) over FEV1 (6.893) and FEF50 (4.001) could be found. Moreover, the so-called dysanapsis, and changes of end-expiratory lung volume were found to be important determinants of AHR. Conclusions Applying plethysmographic tidal breathing analysis in addition to spirometry in MCTs provides relevant advantages. The absence of deep and maximal inhalations and forced expiratory manoeuvres improve the subject's cooperation and coordination, and provide sensitive and differentiated test results, improving diagnostic accuracy. Moreover, by the combined assessment, pulmonary hyperinflation and dysanapsis can be respected in the differentiation between "asthmatics" and "non-asthmatics". … (more)
- Is Part Of:
- Respiratory research. Volume 17:Issue 1(2016)
- Journal:
- Respiratory research
- Issue:
- Volume 17:Issue 1(2016)
- Issue Display:
- Volume 17, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 1
- Issue Sort Value:
- 2016-0017-0001-0000
- Page Start:
- 1
- Page End:
- 14
- Publication Date:
- 2016-12
- Subjects:
- (1) Airway hyperreactivity -- (2) Bronchial asthma -- (3) Methacholine challenge test -- (4) Whole-body plethysmography -- (5) Effective, specific airway conductance -- (6) Diagnostic accuracy -- (7) Dysanapsis
Respiratory organs -- Diseases -- Periodicals
616.2005 - Journal URLs:
- http://pubmedcentral.nih.gov/tocrender.fcgi?journal=80 ↗
http://respiratory-research.com/home ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12931-016-0470-0 ↗
- Languages:
- English
- ISSNs:
- 1465-993X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9959.xml