Classification of hemodynamically significant stenoses from dynamic CT perfusion and CTA myocardial territories. Issue 4 (22nd March 2017)
- Record Type:
- Journal Article
- Title:
- Classification of hemodynamically significant stenoses from dynamic CT perfusion and CTA myocardial territories. Issue 4 (22nd March 2017)
- Main Title:
- Classification of hemodynamically significant stenoses from dynamic CT perfusion and CTA myocardial territories
- Authors:
- Giordano, Marco
Poot, Dirk H.J.
Coenen, Adriaan
van Walsum, Theo
Tezza, Michela
Nieman, Koen
Niessen, Wiro J. - Abstract:
- Abstract : Purpose: Myocardial blood flow (MBF) obtained by dynamic CT perfusion (CTP) has been recently introduced to assess hemodynamic significance of coronary stenosis in coronary artery disease. The diagnostic performance of dynamic CTP MBF is limited due to subjective interpretation of MBF maps and MBF variations caused by physiological, methodological, and technical issues. In this paper, we introduce a novel method to quantify the hypoperfused volume (HPV) in myocardial territories derived from CT angiography (CTA) to overcome the limitations of current dynamic CTP MBF analysis methods. Methods: The diagnostic performance of HPV in classifying significant stenoses was evaluated on 22 patients (57 vessels) that underwent CTA, CTP and invasive fractional flow reserve (FFR). FFR was used as the standard of reference to determine stenosis significance. The diagnostic performance was compared to that of the mean MBF computed in regions manually annotated by an expert (MA‐MBF). HPV was derived by thresholding the MBF in myocardial territories constructed from CTA by locating the closest artery. Diagnostic performance was evaluated using leave‐one‐case out cross‐validation. Inter‐observer reproducibility was assessed by performing annotations of coronary seeds (HPV) and manual regions (MA‐MBF) with two users. In addition, the influence of different parameter settings on the diagnostic performance of HPV was assessed. Results: Leave‐one‐case out cross‐validation showed thatAbstract : Purpose: Myocardial blood flow (MBF) obtained by dynamic CT perfusion (CTP) has been recently introduced to assess hemodynamic significance of coronary stenosis in coronary artery disease. The diagnostic performance of dynamic CTP MBF is limited due to subjective interpretation of MBF maps and MBF variations caused by physiological, methodological, and technical issues. In this paper, we introduce a novel method to quantify the hypoperfused volume (HPV) in myocardial territories derived from CT angiography (CTA) to overcome the limitations of current dynamic CTP MBF analysis methods. Methods: The diagnostic performance of HPV in classifying significant stenoses was evaluated on 22 patients (57 vessels) that underwent CTA, CTP and invasive fractional flow reserve (FFR). FFR was used as the standard of reference to determine stenosis significance. The diagnostic performance was compared to that of the mean MBF computed in regions manually annotated by an expert (MA‐MBF). HPV was derived by thresholding the MBF in myocardial territories constructed from CTA by locating the closest artery. Diagnostic performance was evaluated using leave‐one‐case out cross‐validation. Inter‐observer reproducibility was assessed by performing annotations of coronary seeds (HPV) and manual regions (MA‐MBF) with two users. In addition, the influence of different parameter settings on the diagnostic performance of HPV was assessed. Results: Leave‐one‐case out cross‐validation showed that HPV has an accuracy of 72% (58–83%) with sensitivity of 72% (47–90%) and specificity of 72% (58–83%). The accuracy of MA‐MBF was 70% (57–82%) with a sensitivity of 50% (26–74%) and a specificity of 79% (64–91%). The Spearman correlation and the kappa statistic was ( ρ = 0.94, κ = 0.86) for HPV and ( ρ = 0.72, κ = 0.82) for MA‐MBF. The influence of parameter settings on HPV based diagnostic performance was not significant. Conclusions: The proposed HPV accurately classifies hemodynamically significant stenoses with a level of accuracy comparable to the mean MBF in regions annotated by an expert. HPV improves inter‐observer reproducibility as compared to MA‐MBF by providing a more objective criterion to associate the stenotic coronary with the supplied myocardial territory. … (more)
- Is Part Of:
- Medical physics. Volume 44:Issue 4(2017)
- Journal:
- Medical physics
- Issue:
- Volume 44:Issue 4(2017)
- Issue Display:
- Volume 44, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 44
- Issue:
- 4
- Issue Sort Value:
- 2017-0044-0004-0000
- Page Start:
- 1347
- Page End:
- 1358
- Publication Date:
- 2017-03-22
- Subjects:
- coronary CTA -- coronary stenosis -- dynamic CT perfusion -- fractional flow reserve -- Myocardial blood flow
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.12126 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9924.xml