Deterministic absorbed dose estimation in computed tomography using a discrete ordinates method. Issue 7 (11th June 2015)
- Record Type:
- Journal Article
- Title:
- Deterministic absorbed dose estimation in computed tomography using a discrete ordinates method. Issue 7 (11th June 2015)
- Main Title:
- Deterministic absorbed dose estimation in computed tomography using a discrete ordinates method
- Authors:
- Norris, Edward T.
Liu, Xin
Hsieh, Jiang - Abstract:
- Abstract : Purpose: Organ dose estimation for a patient undergoing computed tomography (CT) scanning is very important. Although Monte Carlo methods are considered gold‐standard in patient dose estimation, the computation time required is formidable for routine clinical calculations. Here, the authors instigate a deterministic method for estimating an absorbed dose more efficiently. Methods: Compared with current Monte Carlo methods, a more efficient approach to estimating the absorbed dose is to solve the linear Boltzmann equation numerically. In this study, an axial CT scan was modeled with a software package, Denovo, which solved the linear Boltzmann equation using the discrete ordinates method. The CT scanning configuration included 16 x‐ray source positions, beam collimators, flat filters, and bowtie filters. The phantom was the standard 32 cm CT dose index (CTDI) phantom. Four different Denovo simulations were performed with different simulation parameters, including the number of quadrature sets and the order of Legendre polynomial expansions. A Monte Carlo simulation was also performed for benchmarking the Denovo simulations. A quantitative comparison was made of the simulation results obtained by the Denovo and the Monte Carlo methods. Results: The difference in the simulation results of the discrete ordinates method and those of the Monte Carlo methods was found to be small, with a root‐mean‐square difference of around 2.4%. It was found that the discrete ordinatesAbstract : Purpose: Organ dose estimation for a patient undergoing computed tomography (CT) scanning is very important. Although Monte Carlo methods are considered gold‐standard in patient dose estimation, the computation time required is formidable for routine clinical calculations. Here, the authors instigate a deterministic method for estimating an absorbed dose more efficiently. Methods: Compared with current Monte Carlo methods, a more efficient approach to estimating the absorbed dose is to solve the linear Boltzmann equation numerically. In this study, an axial CT scan was modeled with a software package, Denovo, which solved the linear Boltzmann equation using the discrete ordinates method. The CT scanning configuration included 16 x‐ray source positions, beam collimators, flat filters, and bowtie filters. The phantom was the standard 32 cm CT dose index (CTDI) phantom. Four different Denovo simulations were performed with different simulation parameters, including the number of quadrature sets and the order of Legendre polynomial expansions. A Monte Carlo simulation was also performed for benchmarking the Denovo simulations. A quantitative comparison was made of the simulation results obtained by the Denovo and the Monte Carlo methods. Results: The difference in the simulation results of the discrete ordinates method and those of the Monte Carlo methods was found to be small, with a root‐mean‐square difference of around 2.4%. It was found that the discrete ordinates method, with a higher order of Legendre polynomial expansions, underestimated the absorbed dose near the center of the phantom (i.e., low dose region). Simulations of the quadrature set 8 and the first order of the Legendre polynomial expansions proved to be the most efficient computation method in the authors' study. The single‐thread computation time of the deterministic simulation of the quadrature set 8 and the first order of the Legendre polynomial expansions was 21 min on a personal computer. Conclusions: The simulation results showed that the deterministic method can be effectively used to estimate the absorbed dose in a CTDI phantom. The accuracy of the discrete ordinates method was close to that of a Monte Carlo simulation, and the primary benefit of the discrete ordinates method lies in its rapid computation speed. It is expected that further optimization of this method in routine clinical CT dose estimation will improve its accuracy and speed. … (more)
- Is Part Of:
- Medical physics. Volume 42:Issue 7(2015)
- Journal:
- Medical physics
- Issue:
- Volume 42:Issue 7(2015)
- Issue Display:
- Volume 42, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 7
- Issue Sort Value:
- 2015-0042-0007-0000
- Page Start:
- 4080
- Page End:
- 4087
- Publication Date:
- 2015-06-11
- Subjects:
- biomedical equipment -- Boltzmann equation -- collimators -- computerised tomography -- deterministic algorithms -- dosimetry -- estimation theory -- Legendre polynomials -- medical computing -- Monte Carlo methods -- phantoms -- X‐ray apparatus
Dosimetry/exposure assessment -- Computed tomography -- Biomedical instrumentation and transducers, including micro‐electro‐mechanical systems (MEMS) -- Monte Carlo simulations
Computerised tomographs -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Using diaphragms, collimators -- Devices sensitive to very short wavelength, e.g. x‐rays, gamma‐rays or corpuscular radiation -- Transforming x‐rays -- X‐ray technique -- Scintigraphy
patient dose -- deterministic simulation -- discrete ordinates -- computed tomography
Computed tomography -- Dosimetry -- Photons -- Monte Carlo methods -- Polynomials -- Computer simulation -- Boltzmann equations -- Medical imaging -- Photon scattering -- Anisotropy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4922000 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9913.xml