Ion recombination correction in carbon ion beams. Issue 7 (15th June 2016)
- Record Type:
- Journal Article
- Title:
- Ion recombination correction in carbon ion beams. Issue 7 (15th June 2016)
- Main Title:
- Ion recombination correction in carbon ion beams
- Authors:
- Rossomme, S.
Hopfgartner, J.
Lee, N. D.
Delor, A.
Thomas, R. A. S.
Romano, F.
Fukumura, A.
Vynckier, S.
Palmans, H. - Abstract:
- Abstract : Purpose: In this work, ion recombination is studied as a function of energy and depth in carbon ion beams. Methods: Measurements were performed in three different passively scattered carbon ion beams with energies of 62 MeV/n, 135 MeV/n, and 290 MeV/n using various types of plane‐parallel ionization chambers. Experimental results were compared with two analytical models for initial recombination. One model is generally used for photon beams and the other model, developed by Jaffé, takes into account the ionization density along the ion track. An investigation was carried out to ascertain the effect on the ion recombination correction with varying ionization chamber orientation with respect to the direction of the ion tracks. The variation of the ion recombination correction factors as a function of depth was studied for a Markus ionization chamber in the 62 MeV/n nonmodulated carbon ion beam. This variation can be related to the depth distribution of linear energy transfer. Results: Results show that the theory for photon beams is not applicable to carbon ion beams. On the other hand, by optimizing the value of the ionization density and the initial mean‐square radius, good agreement is found between Jaffé's theory and the experimental results. As predicted by Jaffé's theory, the results confirm that ion recombination corrections strongly decrease with an increasing angle between the ion tracks and the electric field lines. For the Markus ionization chamber, theAbstract : Purpose: In this work, ion recombination is studied as a function of energy and depth in carbon ion beams. Methods: Measurements were performed in three different passively scattered carbon ion beams with energies of 62 MeV/n, 135 MeV/n, and 290 MeV/n using various types of plane‐parallel ionization chambers. Experimental results were compared with two analytical models for initial recombination. One model is generally used for photon beams and the other model, developed by Jaffé, takes into account the ionization density along the ion track. An investigation was carried out to ascertain the effect on the ion recombination correction with varying ionization chamber orientation with respect to the direction of the ion tracks. The variation of the ion recombination correction factors as a function of depth was studied for a Markus ionization chamber in the 62 MeV/n nonmodulated carbon ion beam. This variation can be related to the depth distribution of linear energy transfer. Results: Results show that the theory for photon beams is not applicable to carbon ion beams. On the other hand, by optimizing the value of the ionization density and the initial mean‐square radius, good agreement is found between Jaffé's theory and the experimental results. As predicted by Jaffé's theory, the results confirm that ion recombination corrections strongly decrease with an increasing angle between the ion tracks and the electric field lines. For the Markus ionization chamber, the variation of the ion recombination correction factor with depth was modeled adequately by a sigmoid function, which is approximately constant in the plateau and strongly increasing in the Bragg peak region to values of up to 1.06. Except in the distal edge region, all experimental results are accurately described by Jaffé's theory. Conclusions: Experimental results confirm that ion recombination in the investigated carbon ion beams is dominated by initial recombination. Ion recombination corrections are found to be significant and cannot be neglected for reference dosimetry and for the determination of depth dose curves in carbon ion beams. … (more)
- Is Part Of:
- Medical physics. Volume 43:Issue 7(2016)
- Journal:
- Medical physics
- Issue:
- Volume 43:Issue 7(2016)
- Issue Display:
- Volume 43, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 7
- Issue Sort Value:
- 2016-0043-0007-0000
- Page Start:
- 4198
- Page End:
- 4208
- Publication Date:
- 2016-06-15
- Subjects:
- biomedical equipment -- dosimetry -- ionisation chambers
Dosimetry/exposure assessment -- Biomedical instrumentation and transducers, including micro‐electro‐mechanical systems (MEMS) -- Gas‐filled counters: ionization chambers, proportional, and avalanche counters
Measurement of nuclear or x‐radiation -- Tubes for determining the presence, intensity, density or energy of radiation or particles -- Scintigraphy -- with scintillation detectors -- Ionisation chambers
reference dosimetry -- ion recombination correction factors -- carbon ions
Ionization chambers -- Ion beams -- Carbon -- Ionization -- Electric fields -- Electric measurements -- Dosimetry -- Collisional energy loss -- Graphite -- Electron beams
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4953637 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9912.xml