Diagnostic accuracy of nasal nitric oxide for establishing diagnosis of primary ciliary dyskinesia: a meta-analysis. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of nasal nitric oxide for establishing diagnosis of primary ciliary dyskinesia: a meta-analysis. Issue 1 (December 2015)
- Main Title:
- Diagnostic accuracy of nasal nitric oxide for establishing diagnosis of primary ciliary dyskinesia: a meta-analysis
- Authors:
- Kouis, Panayiotis
Papatheodorou, Stefania
Yiallouros, Panayiotis - Abstract:
- Abstract Background To date, diagnosis of Primary Ciliary Dyskinesia (PCD) remains difficult and challenging. We systematically evaluated the diagnostic performance of nasal Nitric Oxide (nNO) measurement for the detection of PCD, using either velum-closure (VC) or non-velum-closure (non-VC) techniques. Methods All major electronic databases were searched from inception until March 2015 using appropriate terms. The sensitivity and specificity of nNO measurement was calculated in PCD patients diagnosed by transmission electron microscopy, high speed video-microscopy or genetic testing. Summary receiver operating characteristic (HSROC) curves were drawn using the parameters of the fitted models. Results Twelve studies provided data for 13 different populations, including nine case–control (n = 793) and four prospective cohorts (n = 392). The overall sensitivity of nNO measured by VC techniques was 0.95 (95 % CI 0.91–0.97), while specificity was 0.94 (95 % CI 0.88–0.97). The positive likelihood ratio (LR+) of the test was 15.8 (95 % CI 8.1–30.6), whereas the negative likelihood ratio (LR-) was 0.06 (95 % CI 0.04–0.09). For non-VC techniques, the overall sensitivity of nNO measurement was 0.93 (95 % CI 0.89–0.96) whereas specificity was 0.95 (95 % CI 0.82–0.99). The LR+ of the test was 18.5 (95 % CI 4.6–73.8) whereas the LR- was 0.07 (95 % CI 0.04–0.12). Conclusions Diagnostic accuracy of nNO measurement both with VC and non-VC maneuvers is high and can be effectively employedAbstract Background To date, diagnosis of Primary Ciliary Dyskinesia (PCD) remains difficult and challenging. We systematically evaluated the diagnostic performance of nasal Nitric Oxide (nNO) measurement for the detection of PCD, using either velum-closure (VC) or non-velum-closure (non-VC) techniques. Methods All major electronic databases were searched from inception until March 2015 using appropriate terms. The sensitivity and specificity of nNO measurement was calculated in PCD patients diagnosed by transmission electron microscopy, high speed video-microscopy or genetic testing. Summary receiver operating characteristic (HSROC) curves were drawn using the parameters of the fitted models. Results Twelve studies provided data for 13 different populations, including nine case–control (n = 793) and four prospective cohorts (n = 392). The overall sensitivity of nNO measured by VC techniques was 0.95 (95 % CI 0.91–0.97), while specificity was 0.94 (95 % CI 0.88–0.97). The positive likelihood ratio (LR+) of the test was 15.8 (95 % CI 8.1–30.6), whereas the negative likelihood ratio (LR-) was 0.06 (95 % CI 0.04–0.09). For non-VC techniques, the overall sensitivity of nNO measurement was 0.93 (95 % CI 0.89–0.96) whereas specificity was 0.95 (95 % CI 0.82–0.99). The LR+ of the test was 18.5 (95 % CI 4.6–73.8) whereas the LR- was 0.07 (95 % CI 0.04–0.12). Conclusions Diagnostic accuracy of nNO measurement both with VC and non-VC maneuvers is high and can be effectively employed in the clinical setting to detect PCD even in young children, thus potentiating early diagnosis. Measurement of nNO merits to be part of a revised diagnostic algorithm with the most efficacious combination of tests to achieve PCD diagnosis. … (more)
- Is Part Of:
- BMC pulmonary medicine. Volume 15:Issue 1(2015)
- Journal:
- BMC pulmonary medicine
- Issue:
- Volume 15:Issue 1(2015)
- Issue Display:
- Volume 15, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2015-0015-0001-0000
- Page Start:
- 1
- Page End:
- 9
- Publication Date:
- 2015-12
- Subjects:
- Primary Ciliary Dyskinesia -- Nitric oxide -- Kartagener syndrome -- Diagnosis
Lungs -- Diseases -- Periodicals
616.24005 - Journal URLs:
- http://www.biomedcentral.com/bmcpulmmed/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=64 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s12890-015-0147-3 ↗
- Languages:
- English
- ISSNs:
- 1471-2466
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9928.xml