Investigation of realistic PET simulations incorporating tumor patientˈs specificity using anthropomorphic models: Creation of an oncology database. Issue 11 (28th October 2013)
- Record Type:
- Journal Article
- Title:
- Investigation of realistic PET simulations incorporating tumor patientˈs specificity using anthropomorphic models: Creation of an oncology database. Issue 11 (28th October 2013)
- Main Title:
- Investigation of realistic PET simulations incorporating tumor patientˈs specificity using anthropomorphic models: Creation of an oncology database
- Authors:
- Papadimitroulas, Panagiotis
Loudos, George
Le Maitre, Amandine
Hatt, Mathieu
Tixier, Florent
Efthimiou, Nikos
Nikiforidis, George C.
Visvikis, Dimitris
Kagadis, George C. - Abstract:
- Abstract : Purpose: : The GATE Monte Carlo simulation toolkit is used for the implementation of realistic PET simulations incorporating tumor heterogeneous activity distributions. The reconstructed patient images include noise from the acquisition process, imaging systemˈs performance restrictions and have limited spatial resolution. For those reasons, the measured intensity cannot be simply introduced in GATE simulations, to reproduce clinical data. Investigation of the heterogeneity distribution within tumors applying partial volume correction (PVC) algorithms was assessed. The purpose of the present study was to create a simulated oncology database based on clinical data with realistic intratumor uptake heterogeneity properties. Methods: : PET/CT data of seven oncology patients were used in order to create a realistic tumor database investigating the heterogeneity activity distribution of the simulated tumors. The anthropomorphic models (NURBS based cardiac torso and Zubal phantoms) were adapted to the CT data of each patient, and the activity distribution was extracted from the respective PET data. The patient‐specific models were simulated with the Monte Carlo Geant4 application for tomography emission (GATE) in three different levels for each case: (a) using homogeneous activity within the tumor, (b) using heterogeneous activity distribution in every voxel within the tumor as it was extracted from the PET image, and (c) using heterogeneous activity distributionAbstract : Purpose: : The GATE Monte Carlo simulation toolkit is used for the implementation of realistic PET simulations incorporating tumor heterogeneous activity distributions. The reconstructed patient images include noise from the acquisition process, imaging systemˈs performance restrictions and have limited spatial resolution. For those reasons, the measured intensity cannot be simply introduced in GATE simulations, to reproduce clinical data. Investigation of the heterogeneity distribution within tumors applying partial volume correction (PVC) algorithms was assessed. The purpose of the present study was to create a simulated oncology database based on clinical data with realistic intratumor uptake heterogeneity properties. Methods: : PET/CT data of seven oncology patients were used in order to create a realistic tumor database investigating the heterogeneity activity distribution of the simulated tumors. The anthropomorphic models (NURBS based cardiac torso and Zubal phantoms) were adapted to the CT data of each patient, and the activity distribution was extracted from the respective PET data. The patient‐specific models were simulated with the Monte Carlo Geant4 application for tomography emission (GATE) in three different levels for each case: (a) using homogeneous activity within the tumor, (b) using heterogeneous activity distribution in every voxel within the tumor as it was extracted from the PET image, and (c) using heterogeneous activity distribution corresponding to the clinical image following PVC. The three different types of simulated data in each case were reconstructed with two iterations and filtered with a 3D Gaussian postfilter, in order to simulate the intratumor heterogeneous uptake. Heterogeneity in all generated images was quantified using textural feature derived parameters in 3D according to the ground truth of the simulation, and compared to clinical measurements. Finally, profiles were plotted in central slices of the tumors, across lines with heterogeneous activity distribution for visual assessment. Results: : The accuracy of the simulated database was assessed against the original clinical images. The PVC simulated images matched the clinical ones best. Local, regional, and global features extracted from the PVC simulated images were closest to the clinical measurements, with the exception of the size zone variability and the mean intensity values, where heterogeneous tumors showed better reproducibility. The profiles on PVC simulated tumors after postfiltering seemed to represent the more realistic heterogeneous regions with respect to the clinical reference. Conclusions: : In this study, the authors investigated the input activity map heterogeneity in the GATE simulations of tumors with heterogeneous activity distribution. The most realistic heterogeneous tumors were obtained by inserting PVC activity distributions from the clinical image into the activity map of the simulation. Partial volume effect (PVE) can play a crucial role in the quantification of heterogeneity within tumors and have an important impact on applications such as patient follow‐up during treatment and assessment of tumor response to therapy. The development of such a database incorporating patient anatomical and functional variability can be used to evaluate new image processing or analysis algorithms, while providing control of the ground truth, which is not available when dealing with clinical datasets. The database includes all images used and generated in this study, as well as the sinograms and the attenuation phantoms for further investigation. It is freely available to the interested reader of the journal athttp://www.med.upatras.gr/oncobase/ . … (more)
- Is Part Of:
- Medical physics. Volume 40:Issue 11(2013)
- Journal:
- Medical physics
- Issue:
- Volume 40:Issue 11(2013)
- Issue Display:
- Volume 40, Issue 11 (2013)
- Year:
- 2013
- Volume:
- 40
- Issue:
- 11
- Issue Sort Value:
- 2013-0040-0011-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2013-10-28
- Subjects:
- Biophysical mechanisms of interaction -- Monte Carlo simulations -- Cancer
cancer -- Monte Carlo methods -- physiological models -- positron emission tomography -- simulation -- tumours
tumor heterogeneity -- realistic simulations -- GATE -- PET database -- anthropomorphic phantoms
Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Scintigraphy -- Measuring half‐life of a radioactive substance
Cancer -- Medical imaging -- Positron emission tomography -- Databases -- Medical image reconstruction -- Anatomy -- Monte Carlo methods -- Computed tomography -- Biomedical modeling -- Image scanners
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4826162 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9934.xml