Idiopathic ventricular arrhythmia originating from the para‐Hisian area: Prevalence, electrocardiographic and electrophysiological characteristics. Issue 1 (19th June 2013)
- Record Type:
- Journal Article
- Title:
- Idiopathic ventricular arrhythmia originating from the para‐Hisian area: Prevalence, electrocardiographic and electrophysiological characteristics. Issue 1 (19th June 2013)
- Main Title:
- Idiopathic ventricular arrhythmia originating from the para‐Hisian area: Prevalence, electrocardiographic and electrophysiological characteristics
- Authors:
- Ban, Ji‐Eun
Chen, Yung‐Lung
Park, Hwan‐Cheol
Kim, Dong‐Hyeok
Lee, Dae‐In
Park, Yae‐Min
Choi, Jong‐Il
Lim, Hong‐Euy
Park, Sang‐Weon
Kim, Young‐Hoon - Abstract:
- Abstract: Background: We investigated the prevalence and the electrocardiographic and electrophysiological characteristics of ventricular arrhythmias (VAs) originating from the para‐Hisian area. Methods: Among 250 patients with idiopathic VAs, 8 (3.2%) had an ablation site in the para‐Hisian region. For comparison with right ventricular (RV) para‐Hisian VAs ( n =6), 27 patients with VAs originating from the posterior RV outflow tract (RVOT) were studied. Results: Para‐Hisian VAs had an R wave in leads I and aVL. The VAs originating from the site below the His bundle region were determined to have a superior axis ( n =4, 50%). A His potential was recorded at the proximal bipole of the successful ablation site in 6 patients. RV para‐Hisian VAs had a narrower QRS width (114±12 ms vs. 139±12 ms, P =0.003), as well as a higher incidence of R waves in lead aVL (83.3% vs. 0%, P <0.001) and QS waves in lead V 1 (83.3% vs. 22.2%, P =0.004) compared to posterior RVOT VAs. A greater R wave amplitude in lead I (1.15±0.34 mV vs. 0.34±0.18 mV, P =0.001) and a smaller R wave amplitude in the inferior leads (0.68±0.23 mV vs. 1.58±0.55 mV, P <0.001), with a higher R wave amplitude ratio in leads II/III (4.2±2.0 vs. 1.1±0.2, P =0.01) were the major ECG characteristics. Conclusions: Para‐Hisian VAs have distinctive electrocardiographic features and can be successfully eliminated without disturbance of atrioventricular conduction.
- Is Part Of:
- Journal of arrhythmia. Volume 30:Issue 1(2014)
- Journal:
- Journal of arrhythmia
- Issue:
- Volume 30:Issue 1(2014)
- Issue Display:
- Volume 30, Issue 1 (2014)
- Year:
- 2014
- Volume:
- 30
- Issue:
- 1
- Issue Sort Value:
- 2014-0030-0001-0000
- Page Start:
- 48
- Page End:
- 54
- Publication Date:
- 2013-06-19
- Subjects:
- Para‐Hisian -- Ventricular arrhythmia -- Radiofrequency catheter ablation
Arrhythmia -- Periodicals
Cardiac pacing -- Periodicals
Arrhythmias, Cardiac
Arrhythmia
Cardiac pacing
Periodicals
Electronic journals
Periodicals
616.128 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1883-2148/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1016/j.joa.2013.04.007 ↗
- Languages:
- English
- ISSNs:
- 1880-4276
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9933.xml