Accuracy of a 3D laser/camera surface imaging system for setup verification of the pelvic and thoracic regions in radiotherapy treatments. Issue 1 (17th December 2012)
- Record Type:
- Journal Article
- Title:
- Accuracy of a 3D laser/camera surface imaging system for setup verification of the pelvic and thoracic regions in radiotherapy treatments. Issue 1 (17th December 2012)
- Main Title:
- Accuracy of a 3D laser/camera surface imaging system for setup verification of the pelvic and thoracic regions in radiotherapy treatments
- Authors:
- Pallotta, Stefania
Simontacchi, Gabriele
Marrazzo, Livia
Ceroti, Marco
Paiar, Fabiola
Biti, Giampaolo
Bucciolini, Marta - Abstract:
- Abstract : Purpose: : The aim of this paper is to investigate the accuracy of a laser/camera surface imaging system (Sentinel) when used on patients treated in the thorax or pelvic regions and to evaluate system employment conditions and patient setup procedures that provide more accurate results. Methods: : The system was tested on two groups of patients for whom different patient setup procedures and Sentinel employment conditions were considered. For the first group of 33 patients (FG) no changes to the usual setup procedures were made and a surface extension limited to the treated region was considered. For the second group of 14 patients (SG) the reproducibility of external body surfaces, including body parts not in close proximity to the treatment site, was optimized and a wider surface was captured. In all cases the system accuracy was evaluated comparing registration results from concurrent Sentinel and cone beam CT (CBCT) acquisitions for a total of 192 occasions. External body surfaces, extracted from planning CT studies, were used as reference in both cases, but for SG also surface data captured by Sentinel system at the first treatment were employed. Results: : In the 90th percentile of the distributions reporting CBCT and Sentinel registration parameters, absolute differences for FG were less than 6.4 mm and 3.8°. Better performances were observed for SG (≤5.7 mm and 2°). Mean absolute differences between three translation and three rotation parameters of CBCTAbstract : Purpose: : The aim of this paper is to investigate the accuracy of a laser/camera surface imaging system (Sentinel) when used on patients treated in the thorax or pelvic regions and to evaluate system employment conditions and patient setup procedures that provide more accurate results. Methods: : The system was tested on two groups of patients for whom different patient setup procedures and Sentinel employment conditions were considered. For the first group of 33 patients (FG) no changes to the usual setup procedures were made and a surface extension limited to the treated region was considered. For the second group of 14 patients (SG) the reproducibility of external body surfaces, including body parts not in close proximity to the treatment site, was optimized and a wider surface was captured. In all cases the system accuracy was evaluated comparing registration results from concurrent Sentinel and cone beam CT (CBCT) acquisitions for a total of 192 occasions. External body surfaces, extracted from planning CT studies, were used as reference in both cases, but for SG also surface data captured by Sentinel system at the first treatment were employed. Results: : In the 90th percentile of the distributions reporting CBCT and Sentinel registration parameters, absolute differences for FG were less than 6.4 mm and 3.8°. Better performances were observed for SG (≤5.7 mm and 2°). Mean absolute differences between three translation and three rotation parameters of CBCT and Sentinel were: less than 3.5 mm and 2.1° and 3.7 mm and 1.3° in FG for thorax and pelvis, respectively, and less than 2.8 mm and 1° and 2.7 mm and 0.9° for pelvis and thorax, respectively, in SG. No advantage in considering surface data captured by Sentinel as a reference instead of the surface extracted from the planning CT was observed. Conclusions: : The accuracy of Sentinel system in detecting errors is influenced by the extension and reliability of the surface used. When the reproducibility of external body surfaces was optimized differences between CBCT and Sentinel registration parameters resulted less than 5.7 mm and 2° in the 90% of the pelvis and thorax considered cases. No advantage in considering a Sentinel acquisition as reference was observed. … (more)
- Is Part Of:
- Medical physics. Volume 40:Issue 1(2013)
- Journal:
- Medical physics
- Issue:
- Volume 40:Issue 1(2013)
- Issue Display:
- Volume 40, Issue 1 (2013)
- Year:
- 2013
- Volume:
- 40
- Issue:
- 1
- Issue Sort Value:
- 2013-0040-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2012-12-17
- Subjects:
- Laser imaging -- Image forming and processing -- Therapeutic applications -- Optimization -- Registration -- Computed tomography
biomedical optical imaging -- computerised tomography -- data acquisition -- feature extraction -- image registration -- laser applications in medicine -- medical image processing -- optimisation -- radiation therapy
laser systems -- patient setup -- surface registration -- accuracy -- CBCT
Computerised tomographs -- Radiation therapy -- Data acquisition and logging -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general
Cone beam computed tomography -- Medical imaging -- Computed tomography -- Surface treatments -- Therapeutics -- Cameras -- Optical devices -- Linear accelerators -- Image registration -- Surface optics
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4769428 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9911.xml