Dosimetric evaluation of synthetic CT relative to bulk density assignment-based magnetic resonance-only approaches for prostate radiotherapy. Issue 1 (December 2015)
- Record Type:
- Journal Article
- Title:
- Dosimetric evaluation of synthetic CT relative to bulk density assignment-based magnetic resonance-only approaches for prostate radiotherapy. Issue 1 (December 2015)
- Main Title:
- Dosimetric evaluation of synthetic CT relative to bulk density assignment-based magnetic resonance-only approaches for prostate radiotherapy
- Authors:
- Kim, Joshua
Garbarino, Kim
Schultz, Lonni
Levin, Kenneth
Movsas, Benjamin
Siddiqui, M.
Chetty, Indrin
Glide-Hurst, Carri - Abstract:
- Abstract Background Magnetic resonance imaging (MRI) has been incorporated as an adjunct to CT to take advantage of its excellent soft tissue contrast for contouring. MR-only treatment planning approaches have been developed to avoid errors introduced during the MR-CT registration process. The purpose of this study is to evaluate calculated dose distributions after incorporating a novel synthetic CT (synCT) derived from magnetic resonance simulation images into prostate cancer treatment planning and to compare dose distributions calculated using three previously published MR-only treatment planning methodologies. Methods An IRB-approved retrospective study evaluated 15 prostate cancer patients that underwent IMRT (n = 11) or arc therapy (n = 4) to a total dose of 70.2-79.2 Gy. Original treatment plans were derived from CT simulation images (CT-SIM). T1-weighted, T2-weighted, and balanced turbo field echo images were acquired on a 1.0 T high field open MR simulator with patients immobilized in treatment position. Four MR-derived images were studied: bulk density assignment (10 HU) to water (MRW ), bulk density assignments to water and bone with pelvic bone values derived either from literature (491 HU, MRW+B491 ) or from CT-SIM population average bone values (300 HU, MRW+B300 ), and synCTs. Plans were recalculated using fixed monitor units, plan dosimetry was evaluated, and local dose differences were characterized using gamma analysis (1 %/1 mm dose difference/distance toAbstract Background Magnetic resonance imaging (MRI) has been incorporated as an adjunct to CT to take advantage of its excellent soft tissue contrast for contouring. MR-only treatment planning approaches have been developed to avoid errors introduced during the MR-CT registration process. The purpose of this study is to evaluate calculated dose distributions after incorporating a novel synthetic CT (synCT) derived from magnetic resonance simulation images into prostate cancer treatment planning and to compare dose distributions calculated using three previously published MR-only treatment planning methodologies. Methods An IRB-approved retrospective study evaluated 15 prostate cancer patients that underwent IMRT (n = 11) or arc therapy (n = 4) to a total dose of 70.2-79.2 Gy. Original treatment plans were derived from CT simulation images (CT-SIM). T1-weighted, T2-weighted, and balanced turbo field echo images were acquired on a 1.0 T high field open MR simulator with patients immobilized in treatment position. Four MR-derived images were studied: bulk density assignment (10 HU) to water (MRW ), bulk density assignments to water and bone with pelvic bone values derived either from literature (491 HU, MRW+B491 ) or from CT-SIM population average bone values (300 HU, MRW+B300 ), and synCTs. Plans were recalculated using fixed monitor units, plan dosimetry was evaluated, and local dose differences were characterized using gamma analysis (1 %/1 mm dose difference/distance to agreement). Results While synCT provided closest agreement to CT-SIM for D95, D99, and mean dose (<0.7 Gy (1 %)) compared to MRW, MRW+B491, and MRW+B300, pairwise comparisons showed differences were not significant (p < 0.05). Significant improvements were observed for synCT in the bladder, but not for rectum or penile bulb. SynCT gamma analysis pass rates (97.2 %) evaluated at 1 %/1 mm exceeded those from MRW (94.7 %), MRW+B300 (94.0 %), or MRW+B491 (90.4 %). One subject's synCT gamma (1 %/1 mm) results (89.9 %) were lower than MRW (98.7 %) and MRW+B300 (96.7 %) due to increased rectal gas during MR-simulation that did not affect bulk density assignment-based calculations but was reflected in higher rectal doses for synCT. Conclusions SynCT values provided closest dosimetric and gamma analysis agreement to CT-SIM compared to bulk density assignment-based CT surrogates. SynCTs may provide additional clinical value in treatment sites with greater air-to-soft tissue ratio. … (more)
- Is Part Of:
- Radiation oncology. Volume 10:Issue 1(2015)
- Journal:
- Radiation oncology
- Issue:
- Volume 10:Issue 1(2015)
- Issue Display:
- Volume 10, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 10
- Issue:
- 1
- Issue Sort Value:
- 2015-0010-0001-0000
- Page Start:
- 1
- Page End:
- 9
- Publication Date:
- 2015-12
- Subjects:
- MR simulation -- Synthetic CT -- Radiotherapy treatment planning -- Radiation oncology
Cancer -- Radiotherapy -- Periodicals
616.9940642 - Journal URLs:
- http://pubmedcentral.com/tocrender.fcgi?journal=402&action=archive ↗
http://www.ro-journal.com/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s13014-015-0549-7 ↗
- Languages:
- English
- ISSNs:
- 1748-717X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9935.xml