Difference in dose‐volumetric data between the analytical anisotropic algorithm, the dose‐to‐medium, and the dose‐to‐water reporting modes of the Acuros XB for lung stereotactic body radiation therapy. (8th September 2016)
- Record Type:
- Journal Article
- Title:
- Difference in dose‐volumetric data between the analytical anisotropic algorithm, the dose‐to‐medium, and the dose‐to‐water reporting modes of the Acuros XB for lung stereotactic body radiation therapy. (8th September 2016)
- Main Title:
- Difference in dose‐volumetric data between the analytical anisotropic algorithm, the dose‐to‐medium, and the dose‐to‐water reporting modes of the Acuros XB for lung stereotactic body radiation therapy
- Authors:
- Mampuya, Wambaka A.
Nakamura, Mitsuhiro
Hirose, Yoshinori
Kitsuda, Kenji
Ishigaki, Takashi
Mizowaki, Takashi
Hiraoka, Masahiro - Abstract:
- Abstract : The purpose of this study was to evaluate the difference in dose‐volumetric data between the analytical anisotropic algorithms (AAA) and the two dose reporting modes of the Acuros XB, namely, the dose to water ( AXB − D w ) and dose to medium ( AXB − D m ) in lung stereotactic body radiotherapy (SBRT). Thirty‐eight plans were generated using the AXB − D m in Eclipse Treatment Planning System (TPS) and then recalculated with the AXB − D w and AAA, using identical beam setup. A dose of 50 Gy in 4 fractions was prescribed to the isocenter and the planning target volume (PTV) D95%. The isocenter was always inside the PTV. The following dose‐volumetric parameters were evaluated; D2%, D50%, D95%, and D98% for the internal target volume (ITV) and the PTV. Two‐tailed paired Student's t‐tests determined the statistical significance. Although for most of the parameters evaluated, the mean differences observed between the AAA, AXB − D m and AXB − D w were statistically significant ( p < 0.05 ), absolute differences were rather small, in general less than 5% points. The maximum mean difference was observed in the ITV D50% between the AXB − D m and the AAA and was 1.7% points under the isocenter prescription and 3.3% points under the D95 prescription. AXB − D m produced higher values than AXB − D w with differences ranging from 0.4 to 1.1% points under isocenter prescription and 0.0 to 0.7% points under the PTV D95% prescription. The differences observed under the PTV D95%Abstract : The purpose of this study was to evaluate the difference in dose‐volumetric data between the analytical anisotropic algorithms (AAA) and the two dose reporting modes of the Acuros XB, namely, the dose to water ( AXB − D w ) and dose to medium ( AXB − D m ) in lung stereotactic body radiotherapy (SBRT). Thirty‐eight plans were generated using the AXB − D m in Eclipse Treatment Planning System (TPS) and then recalculated with the AXB − D w and AAA, using identical beam setup. A dose of 50 Gy in 4 fractions was prescribed to the isocenter and the planning target volume (PTV) D95%. The isocenter was always inside the PTV. The following dose‐volumetric parameters were evaluated; D2%, D50%, D95%, and D98% for the internal target volume (ITV) and the PTV. Two‐tailed paired Student's t‐tests determined the statistical significance. Although for most of the parameters evaluated, the mean differences observed between the AAA, AXB − D m and AXB − D w were statistically significant ( p < 0.05 ), absolute differences were rather small, in general less than 5% points. The maximum mean difference was observed in the ITV D50% between the AXB − D m and the AAA and was 1.7% points under the isocenter prescription and 3.3% points under the D95 prescription. AXB − D m produced higher values than AXB − D w with differences ranging from 0.4 to 1.1% points under isocenter prescription and 0.0 to 0.7% points under the PTV D95% prescription. The differences observed under the PTV D95% prescription were larger compared to those observed for the isocenter prescription between AXB − D m and AAA, AXB − D m and AXB − D w, and AXB − D w and AAA. Although statistically significant, the mean differences between the three algorithms are within 3.3% points. PACS number(s): 87.55.x, 87.55.D‐, 87.55.dk … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 17:Number 5(2016)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 17:Number 5(2016)
- Issue Display:
- Volume 17, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 5
- Issue Sort Value:
- 2016-0017-0005-0000
- Page Start:
- 341
- Page End:
- 347
- Publication Date:
- 2016-09-08
- Subjects:
- Acuros XB -- dose‐to‐water (Dw) -- dose‐to‐medium (Dm) -- AAA (anisotropic analytical algorithm) -- dose‐volumetric data -- stereotactic body radiation therapy
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v17i5.6338 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9923.xml