Determination of spontaneous dicentric frequencies and establishment of dose-response curves after expose of human peripheral blood lymphocytes to low- and high-dose rate 60Co gamma rays – the basis for cytogenetic biodosimetry in Vietnam. (6th December 2018)
- Record Type:
- Journal Article
- Title:
- Determination of spontaneous dicentric frequencies and establishment of dose-response curves after expose of human peripheral blood lymphocytes to low- and high-dose rate 60Co gamma rays – the basis for cytogenetic biodosimetry in Vietnam. (6th December 2018)
- Main Title:
- Determination of spontaneous dicentric frequencies and establishment of dose-response curves after expose of human peripheral blood lymphocytes to low- and high-dose rate 60Co gamma rays – the basis for cytogenetic biodosimetry in Vietnam
- Authors:
- Pham, Ngoc-Duy
Nguyen, Minh-Hiep
Tran, Que
Che, Quang-Tuan
Nguyen, Van-Hung
Phan, Van-Toan
Pham, Van-Dung
Ern Lee, Suen
Vo, Thi-Linh-Tien - Abstract:
- Abstract: Purpose: The purposes of this study are to investigate spontaneous dicentric frequencies and dose–response curves of dicentrics induced by gamma 60 Co for replenishing the data sets used for biodosimetry in Vietnam. Materials and methods: One hundred and four healthy donor blood samples were collected for chromosome aberrations background study, 03 healthy donor blood samples were used for generating the dose–response curves at 1.96 mGy/min and 275 mGy/min. Blood collection, in vitro irradiation, cell culture and harvest, slide preparation and metaphase scoring were performed according to IAEA standard protocol (2011). Blind exposed samples were scored for verifying each curve. Results: The dicentric, fragment and chromatid break frequencies in 106, 310 metaphases of 104 donors were 0.023% ± 0.005%, 0.045% ± 0.007% and 0.101% ± 0.011%, respectively. The dose–response curve for low-dose rate was y = C + (0.0137 ± 0.0055) D + (0.0912 ± 0.0142) D 2 and for high-dose rate was y = C + (0.0337 ± 0.0046) D + (0.0539 ± 0.0031) D 2, where both of them were verified. Conclusion: The data of this study were established for biological dose assessment in cases with low LET of accidental or occupational radiation exposures in the dose range of 0.1–5.0 Gy.
- Is Part Of:
- International journal of radiation biology. Volume 95:Number 3(2019)
- Journal:
- International journal of radiation biology
- Issue:
- Volume 95:Number 3(2019)
- Issue Display:
- Volume 95, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 95
- Issue:
- 3
- Issue Sort Value:
- 2019-0095-0003-0000
- Page Start:
- 307
- Page End:
- 313
- Publication Date:
- 2018-12-06
- Subjects:
- Biodosimetry -- dicentric -- dose–response curve -- radiation emergency
Radiation -- Physiological effect -- Periodicals
Radiobiology -- Periodicals
571.45 - Journal URLs:
- http://www.tandfonline.com/loi/irab20 ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/09553002.2019.1549754 ↗
- Languages:
- English
- ISSNs:
- 0955-3002
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.517900
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 9917.xml