A gate evaluation of the sources of error in quantitative90Y PET. Issue 10 (6th September 2016)
- Record Type:
- Journal Article
- Title:
- A gate evaluation of the sources of error in quantitative90Y PET. Issue 10 (6th September 2016)
- Main Title:
- A gate evaluation of the sources of error in quantitative90Y PET
- Authors:
- Strydhorst, Jared
Carlier, Thomas
Dieudonné, Arnaud
Conti, Maurizio
Buvat, Irène - Abstract:
- Abstract : Purpose: Accurate reconstruction of the dose delivered by 90 Y microspheres using a postembolization PET scan would permit the establishment of more accurate dose–response relationships for treatment of hepatocellular carcinoma with 90 Y. However, the quality of the PET data obtained is compromised by several factors, including poor count statistics and a very high random fraction. This work uses Monte Carlo simulations to investigate what impact factors other than low count statistics have on the quantification of 90 Y PET. Methods: PET acquisitions of two phantoms—a NEMA PET phantom and the NEMA IEC PET body phantom‐containing either 90 Y or 18 F were simulated usinggate . Simulated projections were created with subsets of the simulation data allowing the contributions of random, scatter, and LSO background to be independently evaluated. The simulated projections were reconstructed using the commercial software for the simulated scanner, and the quantitative accuracy of the reconstruction and the contrast recovery of the reconstructed images were evaluated. Results: The quantitative accuracy of the 90 Y reconstructions were not strongly influenced by the high random fraction present in the projection data, and the activity concentration was recovered to within 5% of the known value. The contrast recovery measured for simulated 90 Y data was slightly poorer than that for simulated 18 F data with similar count statistics. However, the degradation was not stronglyAbstract : Purpose: Accurate reconstruction of the dose delivered by 90 Y microspheres using a postembolization PET scan would permit the establishment of more accurate dose–response relationships for treatment of hepatocellular carcinoma with 90 Y. However, the quality of the PET data obtained is compromised by several factors, including poor count statistics and a very high random fraction. This work uses Monte Carlo simulations to investigate what impact factors other than low count statistics have on the quantification of 90 Y PET. Methods: PET acquisitions of two phantoms—a NEMA PET phantom and the NEMA IEC PET body phantom‐containing either 90 Y or 18 F were simulated usinggate . Simulated projections were created with subsets of the simulation data allowing the contributions of random, scatter, and LSO background to be independently evaluated. The simulated projections were reconstructed using the commercial software for the simulated scanner, and the quantitative accuracy of the reconstruction and the contrast recovery of the reconstructed images were evaluated. Results: The quantitative accuracy of the 90 Y reconstructions were not strongly influenced by the high random fraction present in the projection data, and the activity concentration was recovered to within 5% of the known value. The contrast recovery measured for simulated 90 Y data was slightly poorer than that for simulated 18 F data with similar count statistics. However, the degradation was not strongly linked to any particular factor. Using a more restricted energy range to reduce the random fraction in the projections had no significant effect. Conclusions: Simulations of 90 Y PET confirm that quantitative 90 Y is achievable with the same approach as that used for 18 F, and that there is likely very little margin for improvement by attempting to model aspects unique to 90 Y, such as the much higher random fraction or the presence of bremsstrahlung in the singles data. … (more)
- Is Part Of:
- Medical physics. Volume 43:Issue 10(2016)
- Journal:
- Medical physics
- Issue:
- Volume 43:Issue 10(2016)
- Issue Display:
- Volume 43, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 10
- Issue Sort Value:
- 2016-0043-0010-0000
- Page Start:
- 5320
- Page End:
- 5329
- Publication Date:
- 2016-09-06
- Subjects:
- bremsstrahlung -- cancer -- cellular biophysics -- dosimetry -- image reconstruction -- medical image processing -- Monte Carlo methods -- phantoms -- positron emission tomography -- yttrium
Positron emission tomography (PET) -- Dosimetry/exposure assessment -- Cancer -- Dose‐volume analysis -- Applications -- Reconstruction
Radiation therapy -- Biological material, e.g. blood, urine; Haemocytometers -- Digital computing or data processing equipment or methods, specially adapted for specific applications -- Image data processing or generation, in general -- Scintigraphy -- Measuring half‐life of a radioactive substance
PET/CT simulation -- gate -- yttrium‐90 -- quantification
Positron emission tomography -- Image reconstruction -- Photons -- Positrons -- Image scanners -- Coupled channel methods -- Photon scattering -- Medical image contrast -- Biomedical modeling
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4961747 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9911.xml