Development and characterization of a three‐dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Issue 5 (25th April 2014)
- Record Type:
- Journal Article
- Title:
- Development and characterization of a three‐dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Issue 5 (25th April 2014)
- Main Title:
- Development and characterization of a three‐dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry
- Authors:
- McCaw, Travis J.
Micka, John A.
DeWerd, Larry A. - Abstract:
- Abstract : Purpose: : Three‐dimensional (3D) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever‐increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. However, currently available 3D dosimeters require extensive experience to prepare and analyze, and are subject to large measurement uncertainties. This work aims to provide a more readily implementable 3D dosimeter with the development and characterization of a radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Methods: : A film stack dosimeter was developed using Gafchromic ® EBT2 films. The dosimeter consists of 22 films separated by 1 mm‐thick spacers. A Virtual Water™ phantom was created that maintains the radial film alignment within a maximum uncertainty of 0.3 mm. The film stack dosimeter was characterized using simulations and measurements of 6 MV fields. The absorbed‐dose energy dependence and orientation dependence of the film stack dosimeter were investigated using Monte Carlo simulations. The water equivalence of the dosimeter was determined by comparing percentage‐depth‐dose (PDD) profiles measured with the film stack dosimeter and simulated using Monte Carlo methods. Film stack dosimeter measurements were verified with thermoluminescent dosimeter (TLD) microcube measurements. The film stack dosimeter was also used to verify the delivery of anAbstract : Purpose: : Three‐dimensional (3D) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever‐increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. However, currently available 3D dosimeters require extensive experience to prepare and analyze, and are subject to large measurement uncertainties. This work aims to provide a more readily implementable 3D dosimeter with the development and characterization of a radiochromic film stack dosimeter for megavoltage photon beam dosimetry. Methods: : A film stack dosimeter was developed using Gafchromic ® EBT2 films. The dosimeter consists of 22 films separated by 1 mm‐thick spacers. A Virtual Water™ phantom was created that maintains the radial film alignment within a maximum uncertainty of 0.3 mm. The film stack dosimeter was characterized using simulations and measurements of 6 MV fields. The absorbed‐dose energy dependence and orientation dependence of the film stack dosimeter were investigated using Monte Carlo simulations. The water equivalence of the dosimeter was determined by comparing percentage‐depth‐dose (PDD) profiles measured with the film stack dosimeter and simulated using Monte Carlo methods. Film stack dosimeter measurements were verified with thermoluminescent dosimeter (TLD) microcube measurements. The film stack dosimeter was also used to verify the delivery of an intensity‐modulated radiation therapy (IMRT) procedure. Results: : The absorbed‐dose energy response of EBT2 film differs less than 1.5% between the calibration and film stack dosimeter geometries for a 6 MV spectrum. Over a series of beam angles ranging from normal incidence to parallel incidence, the overall variation in the response of the film stack dosimeter is within a range of 2.5%. Relative to the response to a normally incident beam, the film stack dosimeter exhibits a 1% under‐response when the beam axis is parallel to the film planes. Measured and simulated PDD profiles agree within a root‐mean‐square difference of 1.3%. In‐field film stack dosimeter and TLD measurements agree within 5%, and measurements in the field penumbra agree within 0.5 mm. Film stack dosimeter and TLD measurements have expanded ( k = 2) overall measurement uncertainties of 6.2% and 5.8%, respectively. Film stack dosimeter measurements of an IMRT dose distribution have 98% agreement with the treatment planning system dose calculation, using gamma criteria of 3% and 2 mm. Conclusions: : The film stack dosimeter is capable of high‐resolution, low‐uncertainty 3D dose measurements, and can be readily incorporated into an existing film dosimetry program. … (more)
- Is Part Of:
- Medical physics. Volume 41:Issue 5(2014)
- Journal:
- Medical physics
- Issue:
- Volume 41:Issue 5(2014)
- Issue Display:
- Volume 41, Issue 5 (2014)
- Year:
- 2014
- Volume:
- 41
- Issue:
- 5
- Issue Sort Value:
- 2014-0041-0005-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2014-04-25
- Subjects:
- Dosimetry/exposure assessment -- Therapeutic applications -- Dose‐volume analysis -- Dosimetry/exposure assessment -- Algorithms -- Conformal radiation treatment
biomedical equipment -- calibration -- dosimetry -- Monte Carlo methods -- phantoms -- radiation therapy -- thermoluminescent dosimeters
radiochromic film stack dosimeter -- three‐dimensional dosimetry -- Gafchromic® EBT2 film
Radiation therapy -- Testing or calibrating of apparatus or arrangements provided for in groups G01D1/00 to G01D15/00 -- Calibrating of instruments or apparatus -- Measuring radiation intensity -- Scintigraphy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4871781 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9926.xml