In vivo calibration of esophageal pressure in the mechanically ventilated patient makes measurements reliable. Issue 1 (December 2016)
- Record Type:
- Journal Article
- Title:
- In vivo calibration of esophageal pressure in the mechanically ventilated patient makes measurements reliable. Issue 1 (December 2016)
- Main Title:
- In vivo calibration of esophageal pressure in the mechanically ventilated patient makes measurements reliable
- Authors:
- Mojoli, Francesco
Iotti, Giorgio Antonio
Torriglia, Francesca
Pozzi, Marco
Volta, Carlo Alberto
Bianzina, Stefania
Braschi, Antonio
Brochard, Laurent - Abstract:
- Abstract Background Esophageal pressure (Pes) can provide information to guide mechanical ventilation in acute respiratory failure. However, both relative changes and absolute values of Pes can be affected by inappropriate filling of the esophageal balloon and by the elastance of the esophagus wall. We evaluated the feasibility and effectiveness of a calibration procedure consisting in optimization of balloon filling and subtraction of the pressure generated by the esophagus wall (Pew). Methods An esophageal balloon was progressively filled in 36 patients under controlled mechanical ventilation. VBEST was the filling volume associated with the largest tidal increase of Pes. Esophageal wall elastance was quantified and Pew was computed at each filling volume. Different filling strategies were compared by performing a validation occlusion test. Results Fifty series of measurements were performed. VBEST was 3.5 ± 1.9 ml (range 0.5–6.0). Esophagus elastance was 1.1 ± 0.5 cmH2 O/ml (0.3–3.1). Both Pew and the result of the occlusion test differed among filling strategies. At filling volumes of 0.5, VBEST and 4.0 ml respectively, Pew was 0.0 ± 0.1, 2.0 ± 1.9, and 3.0 ± 1.7 cmH2 O (p < 0.0001), whereas the occlusion test was satisfactory in 22 %, 98 %, and 88 % of cases (p < 0.0001). Conclusions Under mechanical ventilation, an increase of balloon filling above the conventionally recommended low volumes warrants complete transmission of Pes swings, but is associated withAbstract Background Esophageal pressure (Pes) can provide information to guide mechanical ventilation in acute respiratory failure. However, both relative changes and absolute values of Pes can be affected by inappropriate filling of the esophageal balloon and by the elastance of the esophagus wall. We evaluated the feasibility and effectiveness of a calibration procedure consisting in optimization of balloon filling and subtraction of the pressure generated by the esophagus wall (Pew). Methods An esophageal balloon was progressively filled in 36 patients under controlled mechanical ventilation. VBEST was the filling volume associated with the largest tidal increase of Pes. Esophageal wall elastance was quantified and Pew was computed at each filling volume. Different filling strategies were compared by performing a validation occlusion test. Results Fifty series of measurements were performed. VBEST was 3.5 ± 1.9 ml (range 0.5–6.0). Esophagus elastance was 1.1 ± 0.5 cmH2 O/ml (0.3–3.1). Both Pew and the result of the occlusion test differed among filling strategies. At filling volumes of 0.5, VBEST and 4.0 ml respectively, Pew was 0.0 ± 0.1, 2.0 ± 1.9, and 3.0 ± 1.7 cmH2 O (p < 0.0001), whereas the occlusion test was satisfactory in 22 %, 98 %, and 88 % of cases (p < 0.0001). Conclusions Under mechanical ventilation, an increase of balloon filling above the conventionally recommended low volumes warrants complete transmission of Pes swings, but is associated with significant elevation of baseline. A simple calibration procedure allows finding the filling volume associated with the best transmission of tidal Pes change and subtracting the associated baseline artifact, thus making measurement of absolute values of Pes reliable. … (more)
- Is Part Of:
- Critical care. Volume 20:Issue 1(2016)
- Journal:
- Critical care
- Issue:
- Volume 20:Issue 1(2016)
- Issue Display:
- Volume 20, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 20
- Issue:
- 1
- Issue Sort Value:
- 2016-0020-0001-0000
- Page Start:
- 1
- Page End:
- 9
- Publication Date:
- 2016-12
- Subjects:
- Esophageal pressure -- Pleural pressure -- Transpulmonary pressure -- Mechanical ventilation -- Protective ventilation -- Ventilator-induced lung injury -- Calibration -- Esophageal balloon catheter -- Esophageal elastance -- Esophageal artifact
Critical care medicine -- Periodicals
616.02805 - Journal URLs:
- http://ccforum.com/currentissue/browse.asp ↗
http://www.biomedcentral.com/1364-8535/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?action=archive&journal=9 ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s13054-016-1278-5 ↗
- Languages:
- English
- ISSNs:
- 1364-8535
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9920.xml