Radiation doses and estimated risk from angiographic projections during coronary angiography performed using novel flat detector. (8th May 2016)
- Record Type:
- Journal Article
- Title:
- Radiation doses and estimated risk from angiographic projections during coronary angiography performed using novel flat detector. (8th May 2016)
- Main Title:
- Radiation doses and estimated risk from angiographic projections during coronary angiography performed using novel flat detector
- Authors:
- Varghese, Anna
Livingstone, Roshan S.
Varghese, Lijo
Kumar, Parveen
Srinath, Sirish Chandra
George, Oommen K.
George, Paul V. - Abstract:
- Abstract : Coronary angiography (CA) procedure uses various angiographic projections to elicit detailed information of the coronary arteries with some steep projections involving high radiation dose to patients. This study intends to evaluate radiation doses and estimated risk from angiographic projections during CA procedure performed using novel flat detector (FD) system with improved image processing and noise reduction techniques. Real‐time monitoring of radiation doses using kerma‐area product (KAP) meter was performed for 140 patients using Philips Clarity FD system. The CA procedure involved seven standard projections, of which five were extensively selected by interventionalists. Mean fluoroscopic time (FT), KAP, and reference air kerma (Ka, r) for CA procedure were 3.24 min (0.5–10.51), 13.99 Gycm 2 (4.02–37.6), and 231.43 mGy (73.8–622.15), respectively. Effective dose calculated using Monte Carlo‐based PCXMC software was found to be 4.9 mSv. Left anterior oblique (LAO) 45° projection contributed the highest radiation dose (28%) of the overall KAP. Radiation‐induced risk was found to be higher in females compared to males with increased risk of lung cancer. An increase of 10%–15% in radiation dose was observed when one or more additional projections were adopted along with the seven standard projections. A 14% reduction of radiation dose was achieved from novel FD system when low‐dose protocol during fluoroscopy and medium‐dose protocol during cine acquisitionsAbstract : Coronary angiography (CA) procedure uses various angiographic projections to elicit detailed information of the coronary arteries with some steep projections involving high radiation dose to patients. This study intends to evaluate radiation doses and estimated risk from angiographic projections during CA procedure performed using novel flat detector (FD) system with improved image processing and noise reduction techniques. Real‐time monitoring of radiation doses using kerma‐area product (KAP) meter was performed for 140 patients using Philips Clarity FD system. The CA procedure involved seven standard projections, of which five were extensively selected by interventionalists. Mean fluoroscopic time (FT), KAP, and reference air kerma (Ka, r) for CA procedure were 3.24 min (0.5–10.51), 13.99 Gycm 2 (4.02–37.6), and 231.43 mGy (73.8–622.15), respectively. Effective dose calculated using Monte Carlo‐based PCXMC software was found to be 4.9 mSv. Left anterior oblique (LAO) 45° projection contributed the highest radiation dose (28%) of the overall KAP. Radiation‐induced risk was found to be higher in females compared to males with increased risk of lung cancer. An increase of 10%–15% in radiation dose was observed when one or more additional projections were adopted along with the seven standard projections. A 14% reduction of radiation dose was achieved from novel FD system when low‐dose protocol during fluoroscopy and medium‐dose protocol during cine acquisitions were adopted, compared to medium‐dose protocol. PACS number(s): 87.50.cm, 87.55.de, 87.55.N, 87.59.cf, 87.59.Dj … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 17:Number 3(2016)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 17:Number 3(2016)
- Issue Display:
- Volume 17, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 3
- Issue Sort Value:
- 2016-0017-0003-0000
- Page Start:
- 433
- Page End:
- 441
- Publication Date:
- 2016-05-08
- Subjects:
- coronary angiography -- angiographic projections -- radiation dose -- effective dose
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1120/jacmp.v17i3.5926 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 9935.xml